29
Air circuit diagram
BSC3200KUV
BSC3200KV
12. Installation and Relocation
Contact the lift supplier from whom the lift was purchased for the installation (setup) and relocation of
the lift.
Have the lift Supplier perform inspections when the lift is relocated.
13. Scrap
Separate ferrous materials, non-ferrous materials, plastics and hydraulic oils to dispose of the lift.
Scrap method, especially disposal of operation oil is obliged to be in conformity to the local law. Please
scrap properly according to the law. If any question, contact lift supplier in advance.
Hook release
detection limit (LS1)
Pneumatic-
electro relay
LS1
Hook release
cylinder
Air cylinder for
arm storage
Selex valve
(SOLA)
Filter regulator
Mechanical valve
Air source
Selex valve
(SOL1)
Filter regulator
Air source
Selex valve
(SOLA)
Selex valve
(SOL1)
Hook release
cylinder
Air cylinder for
arm storage