Directional Power Sensor

Model 4043E

Operation Manual

©Copyright 2021 by Bird Technologies, Inc.

Instruction Book Part Number 920-4043E Rev. A

Содержание 4043E

Страница 1: ...Directional Power Sensor Model 4043E Operation Manual Copyright 2021 by Bird Technologies Inc Instruction Book Part Number 920 4043E Rev A...

Страница 2: ...remove the RF transmission line while RF power is present WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of service or adjustm...

Страница 3: ...6 WARNING Warning notes call attention to a procedure which if not correctly performed could result in personal injury CAUTION Caution notes call attention to a procedure which if not correctly perfo...

Страница 4: ...N DE SEGURIDAD DEL INSTRUMENTO BENUTZUNG WIRD DAS GER T AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN KANN DIE GER TESICHERHEIT BEEINTR CHTIGT WERDEN UTILISATION TOUTE UTILISATION DE CET I...

Страница 5: ...S GER TES GELTEN NUR F R GESCHULTES FACHPERSONAL ZUR VERMEIDUNG GEF HRLICHE ELEKTRISCHE SCHOCKS SIND WARTUNGSARBEITEN AUSSCHLIE LICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUF HREN ENTRENTIEN L EMPLO...

Страница 6: ...send your comments to our Solon Ohio factory This manual may be periodically updated When inquiring about updates to this manual refer to the part number and revision on the title page Chapter Layout...

Страница 7: ...Address 3 PTT 3 Chapter 2 Power Sensor Installation 4 Ethernet Connection 4 Direct PC Ethernet Connection 5 LAN Connection 5 RF Connections 6 PTT Connections 7 Chapter 3 Sensor Operation 8 User Inter...

Страница 8: ...z See Model Identification on page 19 for specific frequency ranges and model features The 4043E sensor also provides a VSWR reading Figure 1 4043E Power Sensor The 4043E Power Sensor uses Ethernet co...

Страница 9: ...e with the Sensor s Web UI and provide the measurement interface PTT Connector Push To Talk terminal is used to prevent spurious alarms during periods when the transmitter is not transmitting see PTT...

Страница 10: ...he factory with the same default IP Address Default IP Address 192 168 3 200 To change the IP address see Set IP Address on page 14 PTT PTT is used to prevent false alarms during periods when the tran...

Страница 11: ...ded to a LAN the IP address must be changed to a unique static IP address or set to DHCP Direct PC Connection A direct PC connection is a connection between a PC and a single 4043E This connection can...

Страница 12: ...TT will be used see PTT Connections on page 7 9 See Sensor Operation on page 8 for descriptions of the sensor s User Interface LAN Connection A LAN connection is used to allow multiple sensors to be d...

Страница 13: ...newly assigned IP address in the web browsers address box 6 Connect sensor to RF delivery system See RF Connections on page 6 7 If PTT will be used see PTT Connections on page 7 8 See Sensor Operatio...

Страница 14: ...terminals must be in the correct logic state for PTT to operate correctly Note PTT input is a passive connection and requires a 5V TTL signal to operate Figure 6 PTT Connections The PTT settings in t...

Страница 15: ...de by the 4043E Table view displays the current Forward Reflected and VSWR measurements See Figure 7 Figure 7 Web UI Table View Measurement Display The User Interface also provides the following capab...

Страница 16: ...Figure 8 Figure 8 Alarm Settings The alarm function may be enabled or disabled when enabled a measurement exceeding a threshold will display an alarm message in the Table View see Figure 9 When disab...

Страница 17: ...losed logic or disabled see Figure 10 The PTT terminals on the 4043E must be connected to the transmitter in the correct logic state for PTT to operate correctly Figure 10 PTT Options Zero Sensor Zero...

Страница 18: ...and can be configured to send SNMP Trap messages All of the 4043E s SNMP commands can be found in the MIB file GET and SET Commands The SNMP manager can issue a GET request to read settings and power...

Страница 19: ...nality connect to the 4043E User Interface enable Traps and enter the SNMP Manager s IP address See Figure 12 A trap message will be sent to designated host computers whenever the sensor detects an al...

Страница 20: ...not sent if manually cleared Alarm that occurs when the VSWR is above the maximum VSWR setting MinFwdPowerAlarm Trap Site Name Sensor Name MinFwdPower SetPoint Forward Power VSWR Alarm when sensor sta...

Страница 21: ...sor is deployed Each device on a network must have a unique IP address The 4043E sensor may be set to use a Static IP address or set to DHCP and assigned an IP address If Static is chosen a unique IP...

Страница 22: ...rom the product page on the Bird website at www birdrf com 2 Click MENU on the webpage to access the firmware update utility 3 Click the button on the firmware update utility and navigate to the downl...

Страница 23: ...the button to reset the IP Address the Status LED will briefly change to red The IP address to be reset to the default of 192 168 3 200 Reset All Settings Press and hold the reset button for a minimu...

Страница 24: ...be returned for any reason request an Return Material Authorization RMA through the Bird Technologies website All instruments returned must be shipped prepaid and to the attention of the RMA number B...

Страница 25: ...atio Max 12 dB Directivity 25 dB minimum Measurement Accuracy 5 of reading Data Interface Ethernet10 100 1000BASE T auto sensing Version 2 0 IEEE 802 3 Ethernet Data Interface Connector RJ 45 PTT Push...

Страница 26: ...or 4043E 19 Model Identification 0RGHO 7HFK 5HY UHTXHQF 5DQJH 0 WR 0 0 WR 0 0 WR 0 0 WR 0 0 WR 0 0 WR 0 0 WR 0 3RZHU 5DQJH WR RPPXQLFDWLRQV RQQHFWRUV 2XWSXW WKHUQHW QSXW 1 7 SH IHPDOH 1 7 SH PDOH 0LQL...

Страница 27: ...y such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten 10 days from the date of discovery of the defect The above warranties shall not exte...