6
Coolant
For operation at 1kHz or lower, use only distilled water as the
coolant. For operation above 1kHz use distilled or potable water.
Refer to the specifications for the definition of potable water. If the
water quality is doubtful, use distilled water.
Hoses
The Econoload is supplied with standard 3/4” hose fittings. For rigid
piping, replace the hose adapters with 1/2” male pipe fittings. If the
optional flow switch is installed, it is attached to the water INPUT.
y
The Econoload’s water INPUT is located in the center of the back
of the load. Connect the coolant supply to the load’s INPUT.
Secure with hose clamps.
y
The Econoload’s water OUTPUT is on the rear side of the load, at
a 90° angle to the INPUT. Connect the coolant drain to the load’s
OUTPUT. Secure with hose clamps.
CAUTION
Incorrect hose connections will reverse coolant flow and
could destroy the load.