Страница 1: ...Model EOS7177 PQ INSTALLATION OPERATION MANUAL BIOTEK ENVIRONMENTAL SCIENCE LTD www besgroups com Electrolytic Ozone WATER DISINFECTION SYSTEM ...

Страница 2: ......

Страница 3: ...ICULAR PURPOSE 2020 Biotek Environmental Science Ltd BES COPYRIGHT All Rights Reserved Reproduction adaptation or translation without prior written permission is prohibited Except as allowed under the copyright laws VERSION EOS7177_PQ_V2001_EN Thank you for choosing BioSure equipment This manual contains basic installation operation and maintenance instructions for BioSure Professional Model EOS71...

Страница 4: ...NENTS 7 1 3 SPECIFICATIONS 2 INSTALLATION 2 1 PRECAUTIONS BEFORE INSTALLATION 2 2 INSTALLING THE UNIT 2 3 REMOVE THE UNIT 3 OPERATION 3 1 CONTROL KEYS INDICATORS 3 2 OPERATION MENU 4 MAINTENANCE 5 TROUBLESHOOTING 6 WARRANTY INFORMATION 4 1 EXPECTED CELL LIFE 4 2 CELL CARTRIDGE REPLACEMENT EOS7177_PQ_V2001_EN 3 3 OPERATION SETTINGS STATUS 3 4 SYSTEM CONFIGURATION GUIDES 8 9 7 9 15 21 ...

Страница 5: ...ENTS Wall Mount Phillips Screws x2 Plastic Drywall Wall Anchors x2 Plumber s Tape x1 Main Device attachments include ozone generator cartridge x1 and connector caps x4 Owner s Manual Manual Power Plug Cord Power Supply ...

Страница 6: ...WARNING WARNING indicates a hazardous situation which if not avoided COULD result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided COULD result in injury or property damage NOTICE is used to address practice that is required and must be followed Do NOT damage the Power Supply and Power Plug Cord A damaged Power Supply or Power Plug Cord can cause a fi...

Страница 7: ...hock or injury Do NOT use the product if the power plug is loosely inserted into the electrical outlet A loosely inserted power plug may cause a fire electric shock or short circuit Before using make sure the Power Plug are inserted into the electrical outlet completely and securely If the blades or surface of the power plug become soiled wipe them clean before using A dirty power plug may cause a...

Страница 8: ...TION A short Power Cord is provided for your safety To reduce risks from entanglement or tripping using longer Power Cord is not recommended Extension cord should only be used if care is exercised In cases If extension cord is used The marked electrical rating of the extension cord should be at least as high as the electrical rating of the product The extension cord should have a ground type 3 pro...

Страница 9: ...y loose parts received with device They may be required for proper and safe installation and operation Never attempt any servicing while unit is wet Be sure to turn power OFF and disconnect from power source before any service work is performed Failure to do so could result in serious injury or death Ensure power and water supply meet requirements as indicated in the product specifications Failure...

Страница 10: ... depending on the way of installation and configuration The system applies a revolutionary advanced electrolytic ozone technology which features on demand contribution of reliable sanitizing benefits of dissolved ozone in effective and safe manners in water treatment establishments 1 2 KEY COMPONENTS Head Item Part Name 1 Water Inlet 3 4 NPT 2 Water Outlet 3 4 NPT 3 Cell Power Socket for dissolved...

Страница 11: ...6 GPM Max 2300 LPH 10 0 GPM Pressure Min 0 5 kg cm2 8 psi Max 7 0 kg cm2 100 psi Optimal Temp 5 C 40 C 41 F 104 F ELECTRICAL Power Adaptor Input AC 100 240V 50 60Hz Adaptor Output DC 24V 4A Rate 96W AMBIENT AIR Temp 0 C 40 C 32 F 104 F Humidity 0 90 non condensing humidity DIMENSIONS W x D x H 140 x 128 5 x 210 5 mm 5 51 x 5 06 x 8 23 WEIGHT Net 1 3 kg 2 9 lbs Filled 1 8 kg 4 0 lbs IP CLASS IP56 C...

Страница 12: ...cted to a switched electrical outlet Electrical Plumbing For best performance use cold tap water and filter the input water to 1µm Ensure adequate back flow protection is provided to comply with all national and local standards and codes Do NOT over tighten the connections It is recommended that plastic fittings be used when connecting to the plastic connections of the product This will reduce the...

Страница 13: ...placement Recommended minimum Vertical Clearance is 30cm 12 It is highly recommended that a water shut off valve be installed before and near the WDS unit Other equipment or objects should not lean on or press against the device Water Line Pre Filter Flow Shut Off Valve recommended 300mm 2 Do NOT mount the system above any electrical equipment or items that may be damaged if they get wet 3 Note th...

Страница 14: ... has mounting holes to secure the body of the unit to a wall Please follow the previous section Precautions before installation to select an appropriate location and mark it Secure the Mounting Bracket into wall studs or with the appropriate heavy duty mounting hardware Connect the Cell Power Plug to the Cell Power Socket on the Head Match the anti rotation notch and pin ...

Страница 15: ...ould be mounted close to the system inlet and sized properly for the inlet plumbing line This valve will allow for the following two functions Easier servicing and future cell cartridge replacement Configuring flow as well as dissolved ozone concentrations 5 Use 3 4 fitting for WATER IN and WATER OUT connections Connecting smaller diameter tubing will increase dynamic flow loss in the output perfo...

Страница 16: ...Shut off valve before the unit 3 Open the faucet or tap closest downstream to the device 4 Loosen the connectors of water inlet and outlet 5 Take off the unit Use proper tools if necessary 6 Restore water line You may tilt the body slightly to drain the remaining water in the unit from the water outlet 00 00 NOTICE Before connecting the unit to power supply ensure all plumbing connections are secu...

Страница 17: ...ration Dosage level indicator Blue LED 100 dissolved ozone performance 50 as standard when off Operation indicator Green LED Dissolved ozone dosage is activated Alarm indictor Yellow LED Slow blinking system error detected in POST Power On Self Testing Fast blinking system error detected while the unit is on duty Steady solid on replace cellcartridge now For detail regarding all error codes refer ...

Страница 18: ... Extension Control Program Time Dosage Frequency Schedule Time Setup or change current time Program Program switching schedule and frequency settings Schedule Activation schedule for hourly basis 00 23 on the hour Frequency Program switching frequency in scheduled operating hour options including 1 Initial 30 second dosage in 3 minute cycle 2 Initial 60 second dosage in 5 minute cycle 3 Initial 90...

Страница 19: ...nfigured Program ONLY functions when the use of timer control or Combo is selected The configured Extension ONLY functions when the use of flow switch is selected 3 3 OPERATION SETTINGS STATUS Setting Current Time Step 1 Enter MENU and then select Timer Step 2 Select Time to set Hour and Minute 12 00 Timer ESC OK Life Check Settings Press MENU Select Timer and confirm with OK Select Time and confi...

Страница 20: ...Timer is selected the unit operates according to the set schedule and frequency the set program following the set current local time The unit will always start precisely on the hour according to the programmed schedule and the operation will line up to the programmed frequency However after the first operation a flow 60LPH 0 26 GPM must exist for at least a time of greater than one 1 second before...

Страница 21: ...then select Timer Press MENU Select Timer and confirm with OK 12 01 Timer ESC OK Life Check Settings 12 01 Time ESC OK Program ESC OK 12 01 Schedule Frequency ESC OK 12 01 00 OFF OFF OFF 01 02 ESC OK 12 01 07 OFF OFF OFF 08 09 ESC OK 12 01 07 OFF ON OFF 08 09 To switch setting among 24 hours 00 23 use To switch ON or OFF for desired set hour use Confirm with OK OK OK OK Timer MENU Program Schedule...

Страница 22: ...rd Boost Save Configuring Dosage Step 1 Enter MENU and then select Settings Step 2 Select Dosage and follow on screen options to select desired setting ESC OK 12 01 Timer Settings Life Check Press MENU Select Settings and confirm with OK Select Dosage and confirm with To select desired setting from on screen options use Confirm with OK OK ESC OK 12 01 Control Dosage Extension ESC OK Standard Boost...

Страница 23: ... select desired setting from on screen instructions and options use Confirm with OK OK ESC OK Control Dosage Extension 12 01 60s 120s None ESC OK 12 01 Configuring Extension Step 1 Enter MENU and then select Settings ESC OK 12 01 Timer Settings Life Check Press MENU Select Settings and confirm with OK Press MENU Select Life Check and confirm with OK OK OK OK Settings MENU Extension 60 sec None off...

Страница 24: ...idge is finished for its effective life cycle or an error is detected 4 2 CELL CARTRIDGE REPLACEMENT 1 Unplug the device open the faucet or tap closest downstream to the device 2 Close the inlet water shut off valve and allow the system to depressurize 3 Disconnect the Cell Power Plug from the Cell Power Socket on the Head Slow Quick Blinking Steady Solid ON Detect an error Replace cell 4 Hold bod...

Страница 25: ...ine sanitation Replace cartridge when yellow reminder light turns on Product performance may vary according to flow rate pressure temperature and influent water conditions Use as directed in USER S MANUAL provided Water Max Pressure 7 kg cm2 100psi Optimal Temp 5 40 C 41 104 F Max Temp 50 C 122 F Optimal Quality Clean or filtered water Recommended TDS 60 300 ppm Hardness 180 ppm CaCO3 OPERATING PA...

Страница 26: ...em Possible Cause Corrective Action Error 01 Slow blinking Alarm is ON On screen Display The power cord is not correctly plugged in Plug the power cord in correctly Plug the power cord in correctly Redo the fitting with proper amount of sealant Contact your maintenance person or authorized service agency Retighten or replace the fitting Contact your maintenance person or authorized service agency ...

Страница 27: ...cartridge Contact your maintenance person or authorized service agency The model of dissolved O3 generator cell replacement does not match incorrect model of part is used Error 05 Fast blinking Alarm is ON On screen Display Reconnect the cell and restart the unit If the symptom remains contact your maintenance person or authorized service agency Performance drop may be associated with scaling in t...

Страница 28: ...abor involved in moving adjacent objects to gain access to the Equipment Biotek Environmental Science Ltd is not liable under this warranty for repairs or damages due to alterations abuse fire flood or acts of nature Additionally this warranty may be voided in the case of Failure to follow BES Group instructions for use care or maintenance Removal alteration or defacing of BES Group affixed serial...

Страница 29: ...Memo ...

Страница 30: ...Memo ...

Страница 31: ...Memo ...

Страница 32: ...CONTACT INFORMATION Biotek Environmental Science Ltd www besgroups com 886 2 85111048 info besgroups com ...