12
PLUMBING NOTE
1. Before connecting the fitting to the System Inlet, the plumbing to the unit
must be flushed clear of all debris.
2. Note the flow direction. Connect appropriate size of tubing on the
“WATER IN” and “WATER OUT” sides of the unit.*
3. When making a plumbing connection to the product, always use a good
quality, approved pipe sealant or thread seal tape on pipe threads.
Be careful not to get the pipe sealant inside the pipe when making the
connections.
4. A shut-off valve (not supplied) should be installed in the line leading to the
product as inlet water valve. The valve should be mounted close to the
system inlet and sized properly for the inlet plumbing line. This valve will
allow for the following two functions:
•
Easier servicing and future cell cartridge replacement.
•
Configuring flow as well as dissolved ozone
concentrations.
5. Use 3/4” fitting for “WATER IN” and “WATER OUT” connections.
Connecting smaller diameter tubing will increase dynamic flow loss in the
output performance.
Shut-off Valve
!
NOTICE
•
STEP 3. Starting the Unit
There is no ON/OFF control switch with the unit. The unit is switched ON by
connecting the power supply cord into a wall electrical outlet (power supply).
1. Connect the Power Supply Cord into the Main Power Socket (marked as
"Power") at rear left to the Head. There is a foolproof design to guide you plug
properly.
Anti-Rotation Notch