17
Configuring Controls
ESC
OK
12 : 01
Timer
Settings
Life Check
Step 1. Enter MENU and then select Settings
Press
MENU
.
Select
Settings
and confirm with
.
OK
Select
Control
and confirm with
.
To select desired setting from on-screen options use
.
Confirm with
.
OK
OK
Step 2. Select Control and follow on-screen options to select desired setting
00 : 00
00 : 00
00 : 00
ESC
OK
12 : 01
Flow
Timer
Combo
ESC
OK
12 : 01
Control
Dosage
Extension
ESC
OK
12 : 01
Flow
Timer
Combo
ESC
OK
12 : 01
Flow
Timer
Combo
OK
OK
OK
Settings
MENU
Control
Timer
Flow
Combo
Save
When
Flow
control is selected, the unit is triggered to start and operate
continuously as long as a flow >60LPH (0.26 GPM) is provided and
maintained.
When
Timer
is selected, the unit operates according to the set schedule and
frequency (the set program), following the set current local time. The unit will
always start precisely on the hour according to the programmed schedule,
and the operation will line up to the programmed frequency. However, after
the first operation, a flow >60LPH (0.26 GPM) must exist for at least a time of
greater than one (1) second before the next operation as it is lined up to the
programmed frequency. The unit will have to be able to detect this flow to
continue the operation so that pressure build-up within the cartridge will not
occur. If this check flow is delayed, the next operation will be postponed to
the next available frequency point after the detected check flow.
When
Combo
control is activated, the unit is controlled under both the
triggering of flow switch and timer program (set schedule and frequency).
!
NOTICE
Содержание BioSure Professional EOS7177-PQ
Страница 2: ......
Страница 29: ...Memo ...
Страница 30: ...Memo ...
Страница 31: ...Memo ...
Страница 32: ...CONTACT INFORMATION Biotek Environmental Science Ltd www besgroups com 886 2 85111048 info besgroups com ...