Operation Manual BioSmart
BioSmart PalmJet, BioSmart PalmJet BOX,
BioSmart PalmJet BOX-T
v.049.1|03.2021|en
Page 29 of 39
Figure 25
–
“
System
” tab, “
Operation mode
” setting
The "
Waiting for pass
" parameter. If the value is set to "
Yes
", then after successful identification the
event "
Entry
/
exit is completed
" or "
Entry
/
exit is not completed
" is generated, depending on whether the
employee has passed or not, and the set passage purpose. If the value is set to "
No
", then the employee's
passage is not monitored, and such an event about the passage is not generated.
“Temperature sensor” section
The "
Use temperature sensor
" parameter indicates whether a temperature sensor is used in the
reader's operation.
The "
Lower temperature threshold
" parameter sets the minimum allowable temperature value.
The "
Upper temperature threshold
" parameter sets the maximum allowable temperature value.
The "
Compensation
" parameter sets the value of the compensation correction to be added to the
temperature values measured by the reader.
It’s d
etermined empirically with another thermometer and
depends on the operating conditions.
The "
Number of measurements
" parameter sets the measurements number of the raised hand wrist
temperature. From the totality of these measurements, the minimum and maximum values will be selected
and compared with the threshold values.
The "
Allow passage with high temperature
" parameter allows to set the passage permission for the
user if the measured temperature is beyond the threshold values.
8.3.3
“Diagnostics” Tab
The tab is intended to display statistical data on the reader's connection with BioSmart SmartHub
and self-diagnostics results.