9

that by pressing “enter”, only after that you can complete your 

work, and/or start charging the dispenser. Please note that if 

“enter” is not pressed the dispenser will not start charging, 

even placed in charging stand/connected to AC-adaptor.

NOTE:

 In case you continue to work with the dispenser after 

the low bat-alarm, the battery will eventually be completely 

discharged. Then the battery-symbol and led indicator start 

to blink, and there is no response from operating buttons. 

Charge the dispenser.

Initial charging of 5 minutes is required before use, if the 

battery is totally discharged. During that time the “Load”-text 

is displayed and you can’t use the dispenser. 

When the text disappears from the display, you can continue 

to work with the dispenser keeping it still connected to the 

charger.

4.1.  Charging with the Charging Stand and  

 

Charging Carousel

The Charging Stand and Carousel are desktop charging units. 

The Charging Stand accommodates one eLINE Dispenser and 

Charging Carousel four eLine Dispensers.

The Charging Stands and Carousels operate through the metal 

contacts placed in the sides of the Dispenser and the head of 

the Charging unit.

       

Before operating the AC-adaptor must be connected to the 

socket at the rear of the Charging Stand as well as to the 

electrical outlet. Before connecting the AC-adapter to the 

electrical outlet, check that its voltage setting corresponds 

to the voltage setting of your electrical outlet.

NOTE:

 The Charging Carousel is used to charge the dispenser 

without the tip. If you need to charge the dispenser with the 

tip attached, you can use the Charging Stand with the Tilting 

Piece mounted.

Cat. No.

Product

730981

Charging Stand for one pipette

730991

Charging Carousel for 4 pipettes

Includes Universal AC-adaptor (with EU, UK, US/JPN, AUS, KOR and CHN 
plugs)

Содержание eLINE Dispenser Pro

Страница 1: ...User Manual Bedienungsanleitung Mode d emploi Manual Usuario Instruzioni d impiego eLINE Dispenser Pro...

Страница 2: ...r Manual 1 Bedienungsanleitung 21 Mode d emploi 41 Manual Usario 61 Instruzioni d impiego 81 Specifications 101 Huom Suomenkielinen k ytt ohje ladattavissa osoitteesta www biohit com eLINE Dispenser P...

Страница 3: ...eLINE Dispenser Pro 8 4 1 Charging with the Charging Stand and Charging Carousel 9 4 2 Charging through direct charging system 10 4 3 Charging Recommentations 11 4 4 Electrical specifications 11 5 Pr...

Страница 4: ...handling devices The attractive and ergonomic design of the eLINE pipettes together with electronic tip ejection operation take the effort out of pipetting and reduce the risk of repetitive strain in...

Страница 5: ...or 25 and 50 ml tips Adapter 3 792036 NOTE The tips are disposable do not reuse them 3 Quick start 3 1 Unpacking The Biohit eLINE Dispenser may be delivered with or without an AC adaptor depending on...

Страница 6: ...e battery is protected against discharging during storage with a plastic protector Before use remove the plastic protector 1 Push the charging buttons simultaneuously in order to open the battery cove...

Страница 7: ...ions The control and programming of the eLINE Dispenser is performed using the display keyboard operating buttons and tip Keyboard Display Start button Tip ejection buttons Tip connector eLINE Dispens...

Страница 8: ...on by pressing any key Main Modes and Mode Symbols Custom mode CST Main Modes Operating Mode symbols Aspirating Dispensing direction Battery symbol Speed in out Aliquots counter Volume Selected tip d...

Страница 9: ...the home position and it will empty the contents of the tip The tip is also ejected in the end Select Start button Arrow up down Tip ejection buttons Enter Reset button Press to go back to the Main Mo...

Страница 10: ...above a waste container NOTE When aspirating the liquid using the 25 or 50 ml tip let the tip stay in the liquid a few seconds after the plunger has stopped moving This way you will ensure that all li...

Страница 11: ...Charging with the Charging Stand and Charging Carousel The Charging Stand and Carousel are desktop charging units The Charging Stand accommodates one eLINE Dispenser and Charging Carousel four eLine D...

Страница 12: ...t eLINE Dispenser The socket for the AC adaptor is placed at the back of the dispenser Cat No Product 731600 Biohit eLINE Dispenser AC adaptor with EU UK US JPN AUS KOR and CHN plugs 1 Before connecti...

Страница 13: ...intelligently controlled by a microprocessor NOTE If battery is kept as full as possible it will lengthen its lifetime 4 4 Electrical specifications Battery Rechargeable NiMH battery back with protect...

Страница 14: ...eminder intervals Sr select the desired tip range SET returns default settings Programming is performed by using the Select Enter Arrow and Start keys The main mode range is selected with the Select k...

Страница 15: ...programming See the instructions from the chapter 4 3 Start pipeting Tip confirmation after tip ejection Tip ejection If you want to change the tip size not the mode if you want to continue with the s...

Страница 16: ...will show the best option for the tip size If there are other options the TIP SIZE text is blinking Other options can be observed by pressing the Arrow key Attach the tip to the dispenser before conf...

Страница 17: ...an automatically selected excess volume is aspirated into the tip The excess volume is needes to ensure equal operating conditions for each dispensing step SA the pipette performs consecutive aspirat...

Страница 18: ...onfirming the programming by double clicking the Start button Note If you want to change the speed press the Select key and make the desired changes to the speed before you confirm the pace 5 Choose t...

Страница 19: ...to change the intervals program the GL again according the intstructions above Sr Select tip range SET 1 Push Enter and Start keys 2 Choose the desired operation mode GL Sr SET GL Good Laboratory prac...

Страница 20: ...for proper operation follow these steps for replacement of the battery pack 1 Hold the pipette in a horizontal position with the display facing up 2 Press the two charging contacts simultaneously to r...

Страница 21: ...s no response when pressing the buttons Battery is fully discharged Recharge the battery Leakage or pipetted volume too small Tip incorrectly attached Attached new tip Unsuitable tip Attach firmly Use...

Страница 22: ...e shipping by the manufacturer The Sartorius Quality Assurance Procedure guarantees that the eLINE Dispenser you have purchased is ready for use Each eLINE Dispenser is CE marked fulfilling the requir...

Страница 23: ...0 1000 d 2 1000 100 0 50 0 50 0 20 0 60 1 100 792021 2 5 d 25 2500 d 5 2500 250 0 60 0 60 0 20 0 40 1 100 792022 5 0 d 50 5000 d 10 5000 500 0 60 0 90 0 15 0 50 1 100 792023 10 0 d 100 10 000 d 20 10...

Страница 24: ...us Biohit Helsinki Finland All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius Biohit The statu...