Software
HHR can send request to scale, and after receiving answer with weight, HHR will
put it into the field, or HHR can wait for message send by scale while user press
AVG button.
“TTWeight” function sends request to scale to receive weight, when HHR receive it,
it will be displayed in field on the screen, then user can accept it with Enter Key and
save in Memory. Every time user puts frame (cursor) on HHR LCD to the field
generated by TTWeight a request will be send.
TTAVG function waits to AVG message from scale. If user put frame (cursor) on
field generated by TTAVG, HHR waits for AVG message from Tru-Test scale,
when HHR receives that message, it will save it in memory and move to next field
on the screen.
Both of those function are screen functions, so to activate it, user has to put frame
(screen cursor), when HHR receives message from scale it will save it in DB and
HHR will move to next data field on the screen.
Iconix Scales
HHR can cooperate with Iconix FX21 and FX41 scales. As mentioned upper,
special functions must be used to be able to connect HHR to Iconix. Please refer to
sections below.
Hardware
Please configure scale to use 'Computer' settings in RS232 connection, and
connect HHR with supplied HHR-RS232 cable set (Biocontrol part 55008) and use
null modem RS232 adapter .
Connect gray plug with sticker “CONNECT TO HHR” to HHR and use null
modem adapter on another end of cable to connect to Iconix scale.
D01B2.4 HHR 3000 PRO Manual
72/75
This plug
to HHR3000
This adapter
to Iconix scale