PVC PC Software
The instrument is supplied with the PVC software program (supplied with its own devoted operating manual) on the accompanying USB
flash drive. The instrument can be connected to a PC onto which the PVC software has been installed, via a USB A to USB B cable. This
enables the operator
to “print through” the PC directly to the printer that is connected to it. The data may also be stored as a
comma-
separated value (.csv), enhanced meta file (.emf), Excel spreadsheet (.xlsx, .xls), rich text format (.rtf), tab-separated value (.tsv) or in a native
PVC format file.
Biochrom Resolution PC Software
When connected to a PC the spectrophotometer can be controlled using the Biochrom Resolution PC software packages (sold separately).
Operation using Biochrom Resolution PC software is described in the Resolution user manual or Resolution help file.
Instrument Data Output
A printer accessory is available for the instrument. This is an optional accessory for end-user installation.
Measurement data can also be exported to a USB flash drive via the USB A socket on the side of the instrument, as either a tab-separated
value (.tsv) or native PVC format file.
Performing a Measurement
The optical height (z value) of the instrument is 15 mm. The light path is directed from LEFT to RIGHT through the cell chamber.
The 8-position cell changer supplied as standard with the instrument accepts 10 mm pathlength quartz, glass, or plastic cuvettes. When
using a cuvette with a pathlength less than 10 mm, ensure the cell is inserted to the far right of the cell holder and secured using an
appropriate packing piece.
Please consult the User Interface section of this user manual for more detail on taking a measurement using the spectrophotometer. In
summary, how to perform a measurement is outline below.
1.
Open the desired application on the spectrophotometer.
2.
Insert a cuvette containing the reference sample into cell 1 of the 8-position cell changer and insert a cuvette containing the
sample into cell 2. If measuring more than one sample, insert cuvettes containing samples into cells 2
–
8.
3.
Set the appropriate parameters, moving through the parameter screens.
4.
When you get to the measurements screen, take measurements by pressing the batch measurement icon
; you will be
prompted to load the 8-cell changer and confirm
or cancel
. The acquired reference baseline is applied to any subsequent
sample measurements until a new reference baseline is taken, or the application is closed.
Содержание HB Ultrospec 7500
Страница 1: ...ORIGINAL INSTRUCTIONS 41 56 2050 REV03 1 Ultrospec 7500 Spectrophotometer USER MANUAL...
Страница 2: ...Ultrospec 7500 User Manual 41 56 2050 REV03 2 Intentionally blank...
Страница 6: ...Ultrospec 7500 User Manual 41 56 2050 REV03 6 Intentionally blank...
Страница 103: ...Ultrospec 7500 User Manual 41 56 2050 REV03 103 Intentionally blank...
Страница 104: ......