BRS-CC
2 Product Description
EN - 4
2.4 Abbreviations
Compressed-air connection
G1/4"
Inner width
min. 6 mm
Nominal pressure
6 bar
Working pressure
6-8 bar
Quality of compressed air (ISO 8573-1:2010)
min. class 4
Tab. 4
Pneumatic system - distributor block
4 inputs of the 5/2 directional valves
Activation
24 V DC
Power consumption
4.5 W
Tab. 5
Inputs for activating the directional valves
1 output of inductive proximity switch NO (pnp)
Operating voltage
10 - 30 V DC
Allowed residual ripple
Vss < 10 %
Permanent current
max. 200 mA
Current consumption
approx. 4 mA (24 V)
Voltage drop
approx. 1.2 V (200 mA)
Tab. 6
Electrical system - terminal block
NOTE
To guarantee the maximum power and useful life of the torch maintenance station, operate it with clean
and oiled air.
Tab. 7 Cleaning station BRS-LC on page EN-4
Pneumatic motor / nominal speed with oiled air
approx. 650 rpm
Nominal speed with unoiled air
approx. 550 rpm
Air consumption
approx. 380 l/min
Tab. 7
Cleaning station BRS-LC
Injection unit VI
1 litre
Tab. 8
Injection unit VI
Cutting capacity at 6 bar
Solid wire
up to 1.6 mm
Filler wire
up to 3.2 mm
Cutting time
0.5 seconds
Tab. 9
Wire cutting device DAV (option)
BRS-CC
Short designation of the complete maintenance station (Connect Clean)
BRS-LC
Cleaning station
VI
Injection unit
DAV
Wire cutting device
TCP
Tool Center Point
Tab. 10
Abbreviations
Содержание BRS-CC
Страница 21: ...BRS CC 12 Notizen DE 20 12 Notizen...
Страница 41: ...BRS CC 12 Notes EN 20 12 Notes...
Страница 61: ...BRS CC 12 Notes FR 20 12 Notes...
Страница 81: ...BRS CC 12 Notas ES 20 12 Notas...
Страница 82: ...ES 21 12 Notas BRS CC...
Страница 83: ...BRS CC 12 Notas ES 22...