INSTALLATION INSTRUCTIONS
Step 6. Connect Ducting to Ventilation Hood
Install ducting around starter collar on top or rear of hood and seal according to building code regulations. Be sure to
include a back draft damper in the duct work to prevent drafts.
Step 5. Re-install Liner into Outer Shell
Figure A:
Lift Liner into Shell
Carefully re-install liner to
avoid scratches or damage.
Ensure cables are dressed
carefully to avoid pinching.
Figure B:
Attach Liner to Shell
Re-install with all the screws
removed previously that held
the liner to the hood shell
during shipment.
Figure C:
Re-install Control Panel,
Screen and Filters
Attach button control harness
and light wires. Insert control
panel’s tabs into slots in front of
liner. Drive screws attaching
panel to liner.
Install screen and filters.
1.
Connect Electrical Supply (see Electrical Specifications
on page 7)
a.
Route power cord from liner to outlet location and
plug in.
b.
If alternate direct wire method is desired, remove
power cord from junction box and connect power
supply cable directly in its place being sure to
match wire colors appropriately.
2.
Complete liner
installation by inserting
into hood shell (A),
driving screws (B), and
reinstalling covers and
filters removed
previously (C).
3.
If ductwork is already in
position, be sure to align
properly as liner is
inserted.
a. to outlet
b. power cord
junction box
Turn off power at the service panel prior to wiring the blower.
WARNING
!
bigchill.com
11