HLDA
– Double acting - Doubled thrust hydraulic linear actuator
Use and maintenance manual
© Copyright by BIFFI Italia. All right reserved.
Pag. 8
Contents may change without notice
1.4
DATA SHEET
2
Installation
2.1 CHECKS UPON ACTUATOR RECEIPT
❑
Check that the model, the serial number of the actuator and the
technical data reported on the identification plate correspond with
those of order confirmation (Sect. 1.2).
❑
Check that the actuator is equipped with the fittings as provided for
by order confirmation.
❑
Check that the actuator was not damaged during transportation: if
necessary renovate the painting according to the specification
reported on the order confirmation.
❑
If the actuator is received already assembled with the valve, its
settings have already been made at the factory.
If the actuator is delivered separately from the valve, it is
necessary to check, and, if required, to adjust, the settings of the
mechanical stops (Sect. 3.4) and of micro-switches (if any) (Sect.
3.5).
Supply fluid
Mineral oil or synthetic fluids
Design pressure
Output thrust
350 bar g
Double acting thrust up to 8000000 N
Operating temperature
Standard: from
–30°C to +100°C
Optional: from
–60° to +140°C
Applications
Gate, Globe valves