BIEMMEDUE PHOEN/N 380 Скачать руководство пользователя страница 4

Fig. 1

CONTROL BOARD - TABLEAU DE COMMANDE

0

0

110V

240V

0

110V

240V

5

2

1

3

8

9

10

11

12

6

13

7

15

4

17

14

16

1

CHAMBRE DE COMBUSTION

COMBUSTION CHAMBER

2

BRULEUR

BURNER

3

BAGUE DIFFUSEUR

DIFFUSION RING

4

GROUPE SOUPAPES GAZ

GAS VALVE GROUP

5

VENTILATEUR REFROIDISSEMENT

COOLING FAN

6

VENTILATEUR BRÛLEUR

BURNER FAN

7

RÉGLAGE AIR BRÛLEUR

AIR BURNER REGULATION

8

BOUTON REARMEMENT AVEC LAMPE TEMOIN

RESET BUTTON WITH CONTROL LAMP

9

INTERRUPTEUR CHAUFFAGE-VENTILATION

HEATING-VENTILATION SWITCH

10

PRISE THERMOSTAT D’AMBIANCE

ROOM THERMOSTAT PLUG

11

LAMPE TEMOIN D’ALIMENTATION

CONTROL LAMP

12

CABLE ELECTRIQUE

POWER CORD

13

VOYANT BRÛLEUR

BURNER LIGHT

14

GAS SELECTOR VALVE

VANNE GAZ

15

ELECTRODE D'IONISATION

IIONISATION ELECTRODE

16

PRESSURE PORT

PORTE DE CONTRÔLE PRESSION

17

GAS PRESSURE REGULATOR

RÉGULATEUR PRESSION GAZ

Содержание PHOEN/N 380

Страница 1: ...PHOEN N 380 PHOEN N 380 INSTRUCTIONS MANUAL NATURAL GAS LPG FIRED HEATER Ed 10 09...

Страница 2: ...ntivement toutes les instructions pour l emploi mentionn es ci apr s et d en suivre scrupu leusement les indications Le constructeur n est pas responsable pour les dommages aux choses et ou personnes...

Страница 3: ...equipment before opening doors or removing panels ATTENTION This heater can be washed provided that Ce g n rateur d air chaud peut tre lav l eau condition a Qu il soit pr alablement d branch de l ali...

Страница 4: ...AN 7 R GLAGE AIR BR LEUR AIR BURNER REGULATION 8 BOUTON REARMEMENT AVEC LAMPE TEMOIN RESET BUTTON WITH CONTROL LAMP 9 INTERRUPTEUR CHAUFFAGE VENTILATION HEATING VENTILATION SWITCH 10 PRISE THERMOSTAT...

Страница 5: ...g heated must be sufficiently ventilated so that the heater has enough air to function properly The air suction and or supply pipes are not blocked in any way there are not sheets or covers resting on...

Страница 6: ...rner pressure connect a manometer to the pressure port 16 carry out the pressure reading on the manometer and turn the pressure regulator 17 if necessary to obtain the correct burner pressure value in...

Страница 7: ...ventilated Check that the hot air can escape freely Check that the gas flow or pressure are not excessive Control unit tripped due to irregular burner operation Contact Service Assistance Faulty elec...

Страница 8: ...nes fort risque d incendie ou d explosion Les distances minimales de tout mat riau combustible doivent tre 1 m 3 pieds des parties lat rales et de l aspiration d air 1 5 m 4 pieds de la partie inf rie...

Страница 9: ...t consulter le Tableau I pour rep rer le nouveau type de gaz la pression d alimentation et la condition d utilisation de la soupape de s lection du gaz 13 Pour transformer l appareil un autre type de...

Страница 10: ...on et de l vacuation ne sont pas obstru es V rifier que Le ventilateur tourne librement V rifier le moteur lectrique et le condensateur et les remplacer s ils sont d fectueux Intervention du pressosta...

Страница 11: ...ILOT LAMP LAMPE TEMOIN D ALIMENTATION FU FUSE FUSIBLE LI1 OVERHEAT THERMOSTAT THERMOSTAT DE SURCHAUFFE EV1 SOLENOID VALVE I Stage ELECTROVANNE I Stade MB BURNER MOTOR MOTEUR BRULEUR CO CONDENSER CONDE...

Страница 12: ...P x H in 72 3 x 31 6 x 30 4 Weight Poids lb 306 Dimensions L x W x H Dimensions L x P x H in 74 1 x 26 0 x 35 83 Weight Poids lb 361 Adjustment of combustion air flap R glage du volet d air comburant...

Отзывы: