• The total length of the control cables between the first and
the last unit must not exceed 100m (330ft). If the distance
becomes too great, an additional control panel must be
connected.
• Only units from the same product series, with the same
battery type and of the same capacity can be applied in
combination with a single control panel.
• Configure any single unit as the master. The sequence of
the connected units is not important.
• Connect the control panel and the external control com-
ponents to the master unit.
Note:
n
The master unit can be recognised by the addition
‘Auto’ on the type designation on the type plate.
Note:
n
Do NOT remove the external control input bridges
on the other units.
Operation without control panel
The unit can be operated without control panel. In that event,
only remove the control panel after complete installation.