![Bicker Elektronik UPSI-2412 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/bicker-elektronik/upsi-2412/upsi-2412_user-manual_2749143013.webp)
UPSI-2412
Revision 1
13
GENERAL DATA
Flammability class according to UL 94
V0
Weight
0.125 kg
UPS connection in parallel
No
UPS connection in series
No
Protection type
Non
Protection class
III (without PE)
Mounting type
Built-in device
Housing version
Open Frame
Dimension W / H / D
137 mm / 20 mm / 100 mm ±0.5 mm
(including connectors and highest components)
ENVIRONMENTAL CONDITIONS
Ambient temperature (operation)
-20… +70° C
Ambient temperature (start up without load) -30° C
Ambient temperature
(storage / transport)
-30… +70° C
Max. permitted humidity
≤95 % (at +25° C, no dew)
Operating altitude
≤4000 m
Climate class
3k3 (EN 60721)
Degree of pollution
2
Overvoltage category
EN 61010-1
EN 61010-2-201
I
I
Indoor / Outdoor use
Yes / Yes (end product has to be certified)
STANDARDS
Safety extra-low voltage
IEC 61010-1 (SELV)
IEC 61010-2-201
APPROVALS
UL
n.a.
CSA
CB Scheme
Содержание UPSI-2412