Following is the Example to set different modes of Auto cycle programming.
Function
Code
Sequence of Bytes
Description
06
00 00 00 01
connect
06
00 1A 00 02
micro STEP- 1/2
06
00 12 00 19
CURRNT 2A
10
00 2A 00 08 10 02 0C 02 02 00 00 00 64 00 00 8C A0 00 00
00 00
AUTO C1 RUN CW ANGLE 360 100RPM
10
00 32 00 08 10 03 01 00 00 00 00 00 00 00 00 00 00 00 00
00 00
delay 1SEC
10
00 3A 00 08 10 04 08 02 02 00 00 00 64 00 00 8C A0 00 00
00 00
AUTO
C1
RUN
CCW
ANGLE
360
100RPM
10
00 42 00 08 10 01 01 00 00 00 00 00 00 00 00 00 00 00 00
00 00
DELAY 1 SEC & JMP TO CYCLE1
06
00 25 00 0A
SET AS DEFAULT CODE
06
00 25 00 05
START AUTO CYCLE
06
00 25 00 06
STOP CYCLE
10
00 25 00 03 06 03 00 00 00 00 C8
GO HOME AT 200 RPM
06
00 00 00 01
connect
06
00 1A 00 02
micro STEP- 1/2
06
00 12 00 19
CURRNT 2A
10
00 2A 00 08 10 02 14 02 02 00 00 00 64 00 00 00 02 00 00
00 00
AUTO C1 RUN CW TIME 2SEC 100RPM
10
00 32 00 08 10 03 01 00 00 00 00 00 00 00 00 00 00 00 00
00 00
delay 1SEC
10
00 3A 00 08 10 04 10 02 02 00 00 00 64 00 00 00 02 00 00
00 00
AUTO C1 RUN CCW TIME 2 SEC
100RPM
10
00 42 00 08 10 01 01 00 00 00 00 00 00 00 00 00 00 00 00
00 00
DELAY 1 SEC & JMP TO CYCLE1
06
00 25 00 0A
SET AS DEFAULT CODE
06
00 25 00 05
START AUTO CYCLE
06
00 25 00 06
STOP CYCLE
10
00 25 00 03 06 03 00 00 00 00 C8
GO HOME AT 200 RPM
06
00 00 00 01
connect
06
00 1A 00 02
micro STEP- 1/2
06
00 12 00 19
CURRNT 2A
10
00 2A 00 08 10 02 1C 02 02 00 00 00 64 00 00 01 90 00 00
00 00
AUTO C1 RUN CW STEP 400STEPS
100RPM
10
00 32 00 08 10 03 01 00 00 00 00 00 00 00 00 00 00 00 00
00 00
delay 1SEC
10
00 3A 00 08 10 04 18 02 02 00 00 00 64 00 00 01 90 00 00
00 00
AUTO C1 RUN CCW STEP 400 STEPS
10
00 42 00 08 10 01 01 00 00 00 00 00 00 00 00 00 00 00 00
00 00
DELAY 1 SEC & JMP TO CYCLE1
06
00 25 00 0A
SET AS DEFAULT CODE
06
00 25 00 05
START AUTO CYCLE
06
00 25 00 06
STOP CYCLE
10
00 25 00 03 06 03 00 00 00 00 C8
GO HOME AT 200 RPM