No. of Steps:
0 to 4194303 values
•
Start at switch / Stop at Switch :
Low polarity and high polarity values should be used in the command as shown in
example.
•
Output Status :
Start and stop Status of current cycle
Outputs
Switch
Low
High
1
00
1
2
00
2
3
00
4
4
00
8
5
00
10
6
00
20
7
00
40
8
00
80
Note :
•
If user needs to apply MOVE Commands with gear configurations then PRIMARY
GEAR and SECONDARY GEAR values must be set before AUTO Cycle Program.
•
ANGLE Value should be multiplied by 100 and compounded to integer. e.g. 30.56˚
should be sent as 3056
d
=> 00 00 0B F0 in HEX
•
Time Value is in Second. Factional values are not permissible. e.g. 99 seconds should be
sent as 99d => 00 00 00 63 in HEX