D: (user’s heart rate-target heart rate)<30, speed will reduce 0.6 MPH.
4. The machine will do this evaluation every 30 seconds.
5. If the user's heart rate exceeds (220-AGE), the speed will slow down to 0.6 MPH immediately and
run for 15 seconds. An alarm will sound every second, then the treadmill will stop.
6. If the pulse handle is not in use, the speed will not change. If after two 30 second evaluations and
there is no heart rate signal detected, the speed will slow down to 0.6 MPH and run for 15 seconds with
an alarm every second until stopped.
COMMON ERRORS AND SOLUTIONS
PROBLEM
POSSIBLE CAUSE
SOLUTION
Treadmill does not work
a . No connected to power supply Plug into socket
b. Safety key not inserted
Insert safety key
c . Signal not being received
Check connections to lower
control board
d. Treadmill is not on
Switch on
e. Fuse is broken
Change the fuse
Belt does not run properly
a. Running belt needs lubrication Lubricate board with silicon
b. Running belt is too tight
Adjust running belt
Belt is slipping
a. Running belt is too loose
Adjust running belt
b. Motor belt is too loose
Adjust the motor belt
1. ELECTRONIC ERROR: E01
A:
E01:
The lower control board is having difficulty communicating with the console.
B:
Solution:
Check the 4 lines that connect the console and see if they are connceted properly.
Check for pinched, damaged, or loose cables. Secure the cable connections if they are loose,
replace the cables if damaged.
2. ELECTRONIC ERROR: E02
A:
E02
: The lower control board does not detect motor voltage.
B:
Solution:
Check the + and - connection wires. Make sure they are connected to the + and -
terminals and that the wires are not damaged.
3. ELECTRONIC ERROR: E03
A:
E03
: No speed signal is detected
B:
Solution:
Check to see if the speed sensor is connected securely. Check to see if the sensor
is in line with the magnet on the motor and the gap between them is 3-5mm. If the problem
persists, change the speed sensor.