- 25 -
Control unit
EN
8.4
3ND
LEVEL PROGRAMMING
Description of level 2 parameters
·
: Request for maintenance
: the request for maintenance is not active.
: at the end of the countdown, by means of counters
and
, one of the programmed outputs is activated (see parameter
,
,
,
)
: at the end of the countdown, by means of counters
and
, one of the programmed outputs is activated (see parameter
,
,
,
) and the bar lights fl ash twice.
·
and
: Programming maintenance cycles in thousands and millions
Thanks to the combination of the two parameters the countdown can be set after which a request for maintenance is signalled.
Thousands can be set with the
parameter, millions with the
parameter.
Example: to set 275 000 maintenance manoeuvres set
on 0.2 and
on 75.
The value displayed in the parameters updates along with the manoeuvres.
·
: TERMON (integrated motor heater system).
: system is always ON. Must be used only with maximum ambient temperature less than +10°C
WARNING: ambient temperatures >10°C may cause overheating and damages to the motor, not covered by warranty
: system is actived depending on motor temperature, measured by a NTC sensor (option). In case of NTC failure, system reverts to
setup
·
: UPS
UPS TYPE
Square-wave or quasi-sine wave UPS
Internal detector, UPS input not connected
Pure-sinusoidal wave UPS
with
mains failure output
Connect mains failure output to UPS input
Pure-sinusoidal wave UPS
without
mains failure output
Use 230Vac relais, bobbin connected to mains supply, close contacts to UPS input
·
Arm locking device confi guration:
To use the arm locking device, connect the enabling contact to OUT2 or OUT3 or OUT4 or OUT5 and set the corresponding
parameter
,
,
or
to
. Set advance electric lock disengagement (
-3nd level)
The following table gives the 3rd level functions and the single parameters.
= DEFAULT value set in factory.
= parameter value set during installation: must be indicated if
DEFAULT value is modifi ed.
Par
Function
Settable data
UPS
: disabled
: enabled, opens automatically during mains failure
: enabled, closes automatically during mains failure
ATTENTION:THIS SELECTION MAY BE DANGEROUS
Exiting the menu/saving
Exit programming and view machine Status (see notes
automation Status
display after the 1st level table)
Par
Function
Settable data
Advanced setup
: no advanced setup
: N/A
: controlled entry and automatic exit
PDM dynamic input polarity
: input N.O.
: input N.C.
Output 2 polarity
Output 3 polarity
Output 4 polarity
Output 5 polarity
: N.O.
: N.C.
Advance electric lock disenga-
gement
: 0,5s -
: 1s -
: 1,5s -
: 2s -
: 2,5s -
: 3s
Opening speed (%)
-
(MAXIMA ULTRA 68, ATM 90°, ATM 180°)
-
(MAXIMA ULTRA 35, Carbon)
ENGLISH