- 22 -
Control unit
EN
8. PROGRAMMING
8.1 BASIC FUNCTIONS
To access programming, press button
F
for 2 seconds.
Programming is divided into 4 levels.
To go to the next level keep key
F
pressed and press the
+
key (Sequence 1-2-3-1.......).
After selecting the level wanted, press push button
F
to display the functions available in consecutive order. Each time F is pressed it
corresponds to a function (
-
-
-
.....)
With the function set, use the
+
or
-
key to change the values of the parameters (
+
:
-
-
-
... /
-
: ...
-
-
-
).
The changes made to the parameters are active immediately but will be saved when exiting the menu, selecting the
function with
key
F
.
PLEASE NOTE:
If there is a black out when programming, all changes will be lost.
F
-
+
F
F
2
nd
level
=arm closed
F
F
F
F
F
F
F
F
F
F
F
F
F
+
+
+
+
-
-
-
+
+
+
+
+
+
+
+
x 2”
x 2”
x 5
x 3
x 4
1st level
programming
Selects each
single
1st level
function
(see table par.8.2)
Selects each
single
2nd level
function
(see table par.8.3)
Selects each
single
4th level
function
(see table par.8.5)
Changes the
values
of each single 1st
level function
(see table par.8.2)
Changes the
values
of each single 2nd
level function
(see table par.8.3)
Changes the
values
of each single 4th
level function
(see table par.8.5)
“
”
function
Exit
and
save
programming
2nd level
programming
4th level
programming
Selecting Output2 on closed arm:
A
B
C
D
E
Example:
ENGLISH