           The control unit has been developed to control automatic single-phase barriers with inverter-driven three-phase motor.

1. INTRODUCTION

- Microprocessor logic

- LEDs displaying inputs/outputs status

- Integrated radio receiver 433.92MHz, 2 channels, 2 048 codes

- TCP/IP module and RS485 module (Option)

2. MAIN CHARACTERISTICS

F

J10

J9

J6

J5

J12

J8

J2

J3

J4

J1

F2

F1

F3

F4

J7

J11

K2

K3

K4

K5

PR2

K1

DL

PR1

=    Electrical connections confi gured at the factory.

J1: 

Control unit  power supply

J2: 

Inverter power supply

J3:

 Transformer 

connector

J4: 

Flashing light output

J5: 

Outputs/accessories power supply

J6: 

Encoder/inputs 

J7: 

Inputs/antenna

J8: 

Boom lights connector

J9:

 Inverter 

signals

J10:  

Expansion connector

J12: 

  Radio programmer connector

DL:  

3-digit LED display

START:  

“START” control button

F1:  

Transformer primary fuse:  500 mAT (230Vac) - 1 AT (115Vac) 5x20mm

F2:  

Line fuse (control board and inverter):  4 AT (230Vac) - 8 AT (115Vac)

 

5x20 mm 

F3, F4:   

Transformer secondaries fuses: 2 AT 5x20mm

F, - , + :   

Programming push buttons

PR1, PR2: 

Radio receiver programming push buttons 

- 3-digit display for programming and system status

- Up to 4 confi gurable outputs 

- Radio programmer connector

- Built-in heater for cold climates (Termon)

ANT

SHIELD

ST
AR
T

PDM

OPEN

CLOSE

COM

FTC

ST
OP

8k2

COM

FCA

FCC     

OUT2

OUT3

OUT4

OUT5

+V

SIG.

GND

ENCODER

INVERTER

CH2 RX

24V

ac1

24V

ac2

FRAC

UPS

J7

J6

FWD

REV

B

A

GND

COM

J9

J5

J1

RS 485

OUT

N

J2

230Vac

50-60Hz

OUT

LAMP

230Vac

40W max

230 Vac

INVERTER

N

L

ENGLISH

Содержание CSB Xtreme (1.2)

Страница 1: ...CENTRALE DI COMANDO pag 3 MANUALE D INSTALLAZIONE ED USO CONTROL UNIT pag 17 INSTALLATION AND OPERATION MANUAL IT EN CSB Xtreme 1 2 ...

Страница 2: ...NSION CONNECTOR 21 6 8 J12 RADIO PROGRAMMER CONNECTOR 21 7 INVERTER CONNECTIONS 21 7 1 INVERTER 21 7 2 J2 POWER SUPPLY 21 7 3 M MOTOR 21 7 4 J9 INVERTER SIGNALS 21 8 PROGRAMMING 22 8 1 BASIC FUNCTIONS 22 8 2 1ST LEVEL PROGRAMMING 23 8 3 2ND LEVEL PROGRAMMING 24 8 4 3RD LEVEL PROGRAMMING 25 8 5 4TH LEVEL PROGRAMMING 26 9 RADIO RECEIVER 27 9 1 RECEIVER TECHNICAL SPECIFICATIONS 27 9 2 RADIO CHANNEL F...

Страница 3: ...puts antenna J8 Boom lights connector J9 Inverter signals J10 Expansion connector J12 Radio programmer connector DL 3 digit LED display START START control button F1 Transformer primary fuse 500 mAT 230Vac 1 AT 115Vac 5x20mm F2 Line fuse control board and inverter 4 AT 230Vac 8 AT 115Vac 5x20 mm F3 F4 Transformer secondaries fuses 2 AT 5x20mm F Programming push buttons PR1 PR2 Radio receiver progr...

Страница 4: ... of the appliance 6 INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS OUT24 Output 24Vac 1A max OUT2 Programmable dry relay output max 500mA 24 Vac dc parameter level 2 OUT3 Programmable dry relay output max 500mA 24 Vac dc parameter level 2 OUT4 Programmable dry relay output max 500mA 24 Vac dc parameter level 2 OUT5 CH2 RX Programmable dry relay output max 500mA 24 Vac dc or N O output of the 2nd r...

Страница 5: ...ity over CLOSE command and can be kept always activated until necessary Connect loop detectors clocks daily or weekly timers here where and if necessary FTC COM STOP COM FCA COM FCC COM START COM PDM COM OPEN COM CLOSE COM UPS V BROWN BLACK BLUE SHIELD ANT CLOSE N O input for closing It allows the automation to be closed only if the safety devices have not triggered Operating mode programmable wit...

Страница 6: ...INVERTER CONTROL UNIT INVERTER 7 4 J9 INVERTER SIGNALS 7 2 J2 POWER SUPPLY 7 3 MOTOR M CC Brown F Yellow R White B Gray A Pink GND Green COM Brown FWD Yellow REV White N L 6 6 J8 BOOM LIGHTS CONNECTOR 6 7 J10 EXPANSION CONNECTOR COM GRN RED J2 J9 M FLA OUT NO CC F R S1 S2 P24 FLB FLC CC VI P5 FM B A RS 485 GND COM FWD REV OUT J9 TCP IP SC RS485 ENGLISH ...

Страница 7: ...iting the menu selecting the function with key F PLEASE NOTE If there is a black out when programming all changes will be lost F F F 2nd level arm closed F F F F F F F F F F F F F x 2 x 2 x 5 x 3 x 4 1st level programming Selects each single 1st level function see table par 8 2 Selects each single 2nd level function see table par 8 3 Selects each single 4th level function see table par 8 5 Changes...

Страница 8: ...light when moving and with the arm closed on red light when stopped and on green light when the arm is open Flashing red light when moving off red light when the arm is closed and on green light when the arm is open Flashing red light when moving on red light when the arm is closed and on green light when the arm is open Pause time expres sed in seconds Resetting default parameters see notes after...

Страница 9: ... in factory parameter value set during installation must be indica ted if DEFAULT value is modified Stop due to photocell triggering Opening due to photocell triggering Photocell triggering pause Stop due to encoder triggering Opening due to encoder triggering Pause due to encoder triggering Maximum working time in opening reached Maximum working time in closing reached Par Function Settable data ...

Страница 10: ... or quasi sine wave UPS Internal detector UPS input not connected Pure sinusoidal wave UPS with mains failure output Connect mains failure output to UPS input Pure sinusoidal wave UPS without mains failure output Use 230Vac relais bobbin connected to mains supply close contacts to UPS input Arm locking device configuration To use the arm locking device connect the enabling contact to OUT2 or OUT3 ...

Страница 11: ...en anyway Velocity selection input By enabling this parameter bar speed can be adjusted via the PDM input If the PDM is activated and parameter enabled the barrier moves at a speed equal to 60 of maximum speed both when ope ning and closing Advance electric lock disengagement This parameter adjusts the delay between electo lock deactivation and engine start to allow the resetting of the residual m...

Страница 12: ...ase of standard installations where no advanced functions are required it is possible to proceed to manual storage of the transmitters making reference to programming table A and to the example for basic programming 1 If you wish the transmitter to activate output 1 press pushbutton PR1 otherwise if you wish the transmitter to activate output 2 press pushbutton PR2 2 When LED DL1 starts blinking p...

Страница 13: ... 28 ...

Страница 14: ...ting the barrier closure as long as barrier is occupied ENTRY The recognition system enables bar rier opening IfthecoilS1isnotoccupiedwithinthe pause time the barrier closes again 11 CONTROLLED ENTRY AND AUTOMATIC EXIT S2 S1 PARAMETER DATA DESCRIPTION Automatic The close control closes when pressed and released and also functions as a safety system Advanced Setup controlled entry and automatic exi...

Страница 15: ...ver lights Indicates that scheduled maintenance is required Check the parameters 2ND level 2ND level 2ND level Current from to ground leakage problem the Inverter have a built in high attenuation noise filter and are grounded via a capacitor A switch makes to reduce leakage current from to ground The reducing the load means though non conformity with the EMC standard on the inverter itself Do swit...

Страница 16: ...Signatures 1 Tecnico Technician Cliente Customer 2 Tecnico Technician Cliente Customer 3 Tecnico Technician Cliente Customer 4 Tecnico Technician Cliente Customer 5 Tecnico Technician Cliente Customer 6 Tecnico Technician Cliente Customer 7 Tecnico Technician Cliente Customer 8 Tecnico Technician Cliente Customer 9 Tecnico Technician Cliente Customer 10 Tecnico Technician Cliente Customer REGISTRO...

Страница 17: ...400 Nivelles www bftbenelux be POLAND BFT POLSKA SP Z O O 05 091 ZĄBKI www bft pl CROATIA BFT ADRIA D O O 51218 Drazice Rijeka www bft hr PORTUGAL BFT SA COMERCIO DE AUTOMATISMOS E MATERIAL DE SEGURANCIA 3020 305 Coimbra www bftportugal com CZECH REPUBLIC BFT CZ S R O Praha www bft it TURKEY BFT OTOMATIK KAPI SISTEMELERI SANAY VE Istanbul www bftotomasyon com tr RUSSIA BFT RUSSIA 111020 Moscow www...

Отзывы: