background image

INSTALLATION MANUAL

1) FOREWORD

The ARES actuator is highly versatile in terms of installation options due to the 

extremely low position of the pinion, the actuator’s compact nature and the 

height and depth adjustment features it offers.  The adjustable electronic torque 

limiter provides anti-crush safety. Manual emergency operation is extremely easy 

to perform using just a knob. 

Stopping at end of travel is controlled by electromechanical microswitches.

The built-in control panel controls the start relays and safety devices (photocells, 

safety edge) each time before performing any operation.  

2)  TECHNICAL SPECIFICATIONS 

MOTOR

Power supply

single-phase 230V ±10%, 50Hz (*)

Power input

250 W (ARES 1500)

240 W (ARES 1000)

Pinion module

4mm  (18 teeth)  (ARES 1500/ARES 1000)

4mm (25 teeth)  (ARES 1500V / ARES 1000 V)

Leaf speed

9 m/min   (ARES 1500/ARES 1000)

12 m/min (ARES 1500V / ARES 1000V)

Max. leaf weight

1500 Kg  (ARES 1500)   1000 Kg (ARES 1000)

750 Kg   (ARES 1500V) 500 Kg   (ARES 1000V)

Max. torque

35 Nm (ARES 1500)

30 Nm (ARES 1000)

Impact reaction

Electronic torque limiter

Lubrication

Lifetime greased

Manual operation

Knob-operated mechanical release

Type of use

intensive

Buffer  batteries  (optional 

extras)

Two 12V 1.2Ah batteries

Environmental conditions

from -15°C to +60°C

Protection rating

IP24

Noise level

<70dBA

Operator weight

7 kg

Dimensions

See Fig. K

CONTROL UNIT

Accessories power supply

24V ~ (180 mA)

Fuses

Fig. G

Built-in Rolling-Code radio-receiver frequency 433.92MHz 

Setting  of  parameters  and 

options

Universal handheld programmer/LCD display

N° of combinations

4 billion

Max. n° of remotes that can 

be memorized

63

(*) Special supply voltages to order.

Usable transmitter versions:

All ROLLING CODE transmitters compatible with

3) TUBE ARRANGEMENT Fig.A

Install  the  electrical  system  referring  to  the  standards  in  force  for  electrical 

systems CEI 64-8, IEC 364, harmonization document HD 384 and other national 

standards. 

4)  PREPARATION FOR MOTOR MOUNTING  FIG.B

•  Make a hole in the ground to accommodate the concrete pad, with anchors 

embedded in the base plate for fastening the gearbox assembly, keeping to 

the distances featured in FIG.B.

•  To keep the base plate in the right position during installation, it may be 

useful to weld two iron plates under the track to which the anchors can then 

be welded (FIG.M).

5) MOUNTING THE MOTOR FIG.C

6) MOUNTING DRIVE ACCESSORIES FIG.D-D1

7) RACK CENTRING WITH RESPECT TO PINION FIG.N-O1-P

DANGER - Welding must be performed by a competent person issued 

with the necessary personal protective equipment as prescribed by 

the safety rules in force FIG.O.
8) FASTENING LIMIT SWITCH BRACKETS FIG.E

9) STOPS FIG.Q

DANGER - The gate must be fitted with mechanical stops to halt its 

travel both when opening and closing, thus preventing the gate from 

coming off the top guide. Said stops must be fastened firmly to the ground, 

a few centimetres beyond the electric stop point.
10) MANUAL RELEASE (See USER GUIDE -FIG.2-).

Warning Do not JERK the gate open and closed, instead push it GENTLY to 

the end of its travel.

----------------------------------------------------------

11) TERMINAL BOARD WIRING Fig. F-G

Once suitable electric cables have been run through the raceways and the auto-

mated device’s various components have been fastened at the predetermined 

points, the next step is to connect them as directed and illustrated in the diagrams 

contained in the relevant instruction manuals. Connect the live, neutral and earth 

wire (compulsory). The mains cable must be clamped in the relevant cable gland 

(FIG.R-ref.P1), and the accessories’ wires in the cable gland (FIG.R-ref.P2), while 

the earth wire with the yellow/green-coloured sheath must be connected in the 

relevant terminal (FIG.R-ref.S). 

TERMINAL DESCRIPTION

1-2

Motor connection.

3-4

24V transformer secondary windin (3-, 4+).  

5-6

Closing limit switch SWC (5 Black common - 6 Red).

5-7

Opening limit switch SWO (5 Black common -7 Brown).

8-9

Flashing light 24V max. 25W. 

10-11

Antenna (10 signal - 11 braiding). 

Use an antenna tuned to 433MHz.

Use RG58 coax cable to connect the Antenna and Receiver.

Metal bodies close to the antenna can interfere with radio recep-

tion. If the transmitter’s range is limited, move the antenna to a 

more suitable position.

12-13

Accessories power supply:

24 V operation with mains power on.

24 V (12-,13+) operation with no mains power and optional 

buffer battery kit. 

14-15

Free contact (NO). 

Gate Open Light SCA (24V max. 3W) or 2nd radio channel output 

(FIG.G-ref.1). 

This option can be set via the “logic menu”.

16-17

Safety device power supply output (photocell transmitter and 

safety edge transmitter). 

N.B.: output active only during operating cycle. 

24 V Vsafe operation with mains power on.

24 V  (16 -,17+) Vsafe operation with no mains power and optional 

buffer battery kit. 

18

Safety device test input FAULT - PHOT (N.O.).

19-20

PEDESTRIAN control button (N.O.) 

Opens the gate by the distance set with the “Partial Opening” parameter

21-22

START/CLOSE control button (N.O.). This option can be set via 

the “logic menu”. Start - operation according to 3/4-step logic 

Close - The command causes the leaf to close.

21-23

STOP input (N.C.)

The command stops movement.

If not used, leave jumper inserted.

21-24

PHOTOCELL input (N.C.)

Operation according to photocell during opening logic.

If not used, leave jumper inserted.

21-25

Safety edge input BAR (NC).

The command reverses movement for 2 secs.

If not used, leave jumper inserted.

21-26

OPEN control button (N.O.). 

Gate opened with this command.

27

Safety device test input FAULT - BAR

31-32

230V~ transformer primary winding.

33-34

Single-phase power supply 230V, 50-60Hz (33N - 34L).

12) SAFETY DEVICES

NOTE: ONLY USE RECEIVING SAFETY DEVICES WITH FREE CHANGEOVER 

CONTACT.

12.1) TESTED DEVICES (FIG. U)

12.2) NON-TESTED DEVICES (FIG. H, U)

13) CALLING UP MENUS: FIG. 1

13.1) PARAMETERS MENU (

PARA

)  (PARAMETERS TABLE “A”)

13.2) LOGIC MENU (

LOGIC

) (LOGIC TABLE “B”)

13.3) RADIO MENU (

radio

)  (RADIO TABLE “C”)

-   IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE 

IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).

In the event of manual programming, the first transmitter assigns the RECEIVER’S 

KEY CODE: this code is required to subsequently clone the radio transmitters.

The Clonix built-in on-board receiver also has a number of important advanced 

features: 

•  Cloning of master transmitter (rolling code or fixed code).

•  Cloning to replace transmitters already entered in receiver.

•  Transmitter database management.

•  Receiver community management.

To use these advanced features, refer to the universal handheld programmer’s 

instructions and to the general receiver programming guide.

ARES  -  

21

D811692 00100_01

Содержание ARES Series

Страница 1: ...ANTRIEB FÜR ZAHNSTANGEN SCHIEBETORE SERVOMOTOR PARA CANCELAS CORREDERAS DE CREMALLERA ACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las...

Страница 2: ...tage accessoires overbrenging Fissaggio staffe finecorsa dx e sx Fastening limit switch brackets RH LH Fixation étriers fin de course drt et gch Befestigung Bügel Anschläge rechts und links Fijación abrazaderas final de carrera der e izq Bevestiging stangen aanslag rechts en links Y Y Collegamento morsettiera Terminal board wiring Connexion plaque à bornes Anschluss Klemmleiste Conexión tablero de...

Страница 3: ...II CH 15 JP9 14 15 24 V VSAFE VSAFE 24V 0V 25W max LOGICA test fotocellule OFF Photocell test LOGIC OFF LOGIQUE essai photocellules Désactivée LOGIK Test Fotozellen OFF LÓGICA prueba fotocélulas OFF LOGICA test fotocellen OFF ne ngstasten Display programmeringstoetsen Display tasti programmazio Display programming keys Display Programmieru Pantalla botones programación 1 2 3 4 5 6 7 8 9 10 11 12 1...

Страница 4: ...ing opening 99 99 99 99 99 99 Speed during closing 99 99 99 99 99 99 Partial opening 40 40 40 40 40 40 Zone 0 0 0 0 0 0 Slow down distance 0 0 0 0 0 0 Opening deceleration space 10 10 10 10 10 10 Closing deceleration space 10 10 10 10 10 10 LOGIC Automatic Closing Time OFF ON OFF ON OFF OFF Block Pulses OFF OFF OFF ON ON OFF Impulse lock TCA OFF OFF OFF OFF OFF OFF 3 step OFF ON OFF ON OFF OFF Pre...

Страница 5: ...8888 K N M O P CFZ CP 37 30 12 28 22 22 CVZ 28 60 6 40 KO OK Q R P1 P2 S L O1 100 25 50 25 2mm 2 6 0 1 6 0 1 0 0 300 152 65 2 0 0 Z18 Ø p72 Z25 Ø p100 2 2 4 0 ARES 11 D811692 00100_01 ...

Страница 6: ...20 21 22 23 24 25 26 27 JP2 JP1 31 32 33 34 COM NC BAR2 COM NC SWC NC SWO 24 V 0 V 0 V V Safe V Safe RX RX TX TX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 JP2 JP1 31 32 33 34 COM NC SWC NC SWO FAULT PHOT FAULT BAR 2 FAULT BAR 1 COM NO 24 V V Safe V Safe RX RX TX TX ANT 24V 25W Max 24V 25W Max SCA 2 CH PED COM NO NO NC NO NC NC ST ART CLOSE STOP PHOT BAR1 OPEN U NO SCS...

Страница 7: ... 3 4 5 6 13 12 21 25 17 Bar 2 1 2 3 4 5 6 13 12 27 21 17 Bar 1 1 2 3 4 5 6 13 12 21 25 17 Bar 2 1 2 3 4 5 6 13 12 5 SCS1 MA 4 SCS1 MA 2 SCS1 MA 1 SCS1 MA 17 Bar 3 1 2 3 4 5 6 13 12 27 21 17 6 SCS1 MA Bar 1 1 2 3 4 5 6 13 12 21 25 17 Bar 2 1 2 3 4 5 6 13 12 17 Bar 4 1 2 3 4 5 6 13 12 27 21 17 Bar 3 1 2 3 4 5 6 13 12 5 SCS1 MA 3 SCS1 MA 6 SCS1 MA 4 SCS1 MA 17 26 27 25 24 23 22 21 20 19 18 COM FAULT ...

Страница 8: ...put activated svo opening limit switch input activated svc closing limit switch input activated set the board is standing by to perform a com plete opening closing cycle uninterrupted by intermediate stops in order to acquire the tor que required for movement WARNING Obstacle detection function is not active Er01 photocell test error check photocell connection and or logic settings Er02 safety edg...

Страница 9: ...nnection to the mains power supply use a multicore cable with a cross section of at least 4x1 5mm2 of the kind provided for by the regulations mentioned above by way of example type H05VV F cable can be used with a cross section of 4x1 5mm2 To connect auxiliary equipment use wires with a cross section of at least 0 75 mm2 Have an omnipolar circuit breaker installed with a contact separation of at ...

Страница 10: ...ys and the auto mated device s various components have been fastened at the predetermined points thenextstepistoconnectthemasdirectedandillustratedinthediagrams containedintherelevantinstructionmanuals Connectthelive neutralandearth wire compulsory The mains cable must be clamped in the relevant cable gland FIG R ref P1 and the accessories wires in the cable gland FIG R ref P2 while the earth wire...

Страница 11: ...iliary board must be used 15 4 Interface with WIEGAND systems via SCS WIE module Refer to the SCS WIE module s instructions 13 1 TABLE A PARAMETERS MENU PARA Parameter min max default personal Definition Description tca 0 120 40 Automatic Closing Time Automatic closing time s slov speed 15 50 15 Slow down speed Slow down speed Fig 2 Rif F Set the speed the gate must reach slowing down in percentag...

Страница 12: ... code mode radio prog ON Remote control programming ON Enables wireless memorizing of transmitters 1 Press in sequence the hidden key P1 and normal key T1 T2 T3 T4 of a transmitter that has already been memorized in standard mode via the radio menu 2 Press within 10 secs the hidden key P1 and normal key T1 T2 T3 T4 of a transmitter to be memorized IMPORTANT Enables the automatic addition of new tr...

Страница 13: ...o supervisione o abbiano ricevuto istruzioni d uso da persone responsabili della loro sicurezza I bambini devono essere controllati affinché non giochino con l applicazione Nonlasciareradiocomandioaltridispositividicomandoallaportatadeibambini onde evitare azionamenti involontari L attivazionedellosbloccomanualepotrebbecausaremovimentiincontrollati della porta se in presenza di guasti meccanici o ...

Страница 14: ...l automatisation en particulier pendant son fonctionnement Cette application n est pas destinée à être utilisée par des personnes y compris les enfants ayant des capacités mentales physiques et sensorielles réduites ni par des personnes dépourvues des connaissances nécessaires à moins d agir sous la supervision de personnes responsables de leur sécurité ou d avoir reçues les instructions nécessair...

Отзывы: