2
CONTENTS
General Information . . . . . . . . . . . . . . . . . . . . 2
Use & Safety Considerations . . . . . . . . . . . . . . . . 3
Installation Requirements . . . . . . . . . . . . . . . . . 4
Before You Start . . . . . . . . . . . . . . . . . . . . . . 5
Removing Cover. . . . . . . . . . . . . . . . . . . . . . 5
Installation of Wall Anchors or Screws . . . . . . . . . . . 6
Reinstall the Cover. . . . . . . . . . . . . . . . . . . . . 7
Hose Installation . . . . . . . . . . . . . . . . . . . . 7-8
Connecting the Power Adapter . . . . . . . . . . . . . . 8
System Set Up. . . . . . . . . . . . . . . . . . . . . . . 9
Before Washing Clothes . . . . . . . . . . . . . . . . . 10
Using Your Laundry Pro 2.0 . . . . . . . . . . . . . . . 10
Washers Requiring Hot & Cold Water . . . . . . . . . . . 11
Temp. Control & External Water Tap . . . . . . . . . . . 12
Status Indications . . . . . . . . . . . . . . . . . . . . 12
Frequently Asked Questions . . . . . . . . . . . . . . . 13
Installation Problems . . . . . . . . . . . . . . . . . . 13
Warranty Information . . . . . . . . . . . . . . . . . . 14
PRODUCT OVERVIEW
Laundry Pro 2.0 is designed to work in conjunction with your washing
machine, using cold water and our proprietary ActivePure
®
Technology to
clean clothes. As your washer begins to fill, Laundry Pro 2.0 will turn on.
Laundry Pro 2.0 is equipped with an internal leak sensor. See page 12
for more details.
There’s a smart new approach to laundry that’s based on earth-friendly
science and technology. Laundry Pro 2.0, designed and made in America,
eliminates the need for hot water, detergents, fabric softeners and bleaches,
thereby allowing it to pay for itself over and over again.
Laundry Pro 2.0 is easy to install. It is intended to work with residential clothes
washers and is for use by anyone interested in an economical, earth-friendly
alternative to the typical detergents and chemicals currently available,
without modifying existing appliances, electrical systems, or plumbing.
Laundry Pro 2.0 uses a variation of the technology originally developed for
use in the International Space Station and is recognized as a Certified Space
Technology by the Space Foundation.
FILL IN AND SAVE
The location of the serial number is on the back panel of the water unit,
below the water line connection. Write it here and retain for future
reference.
Model No. ____________________________________________________________
Serial No. ____________________________________________________________
Date of Purchase ______________________________________________________
Aerus Distributor ______________________________________________________
_____________________________________________________________________
Distributor’s Office Phone No. ___________________________________________
_____________________________________________________________________
Distributor’s Office Address _____________________________________________
_____________________________________________________________________
SPECIFICATIONS
AC/DC Adapter:
• AC in: 100 - 240V ~ 50/60 Hz .45A
• DC out: 12V
Power Consumption:
• .4W AC (standby mode)
• 1.3W AC operating
Dynamic Water Pressure:
• Minimum 20 psi to 60 psi / 1.37 ~4.13 bar
Water Temperature:
• Use cold water only (do not use hot water)
Operating Environment:
• 50˚F - 100˚F ( 10˚C - 37.8˚C)
• Humidity 40% ~ 85%
Dimensions:
• 17.3” x 5.19” x 3.69”
• 43.94cm x 13.48cm x 9.37cm
Weight:
• 4.3 lbs
• 1.95 kg
GENERAL INFORMATION