11. After-sales Service

Starting from the date of sales, if the device does not function up to standard due to 

manufacturer defect, our company will be responsible for the repair of device during its warranty 

period. Please refer to the warranty card for warranty period and scope. 

12. Environment Protection

The device does not contain any harmful substances. It may be handled  or disposed in 

accordance with the relevant local regulations.

Note:

1) Without Beyes agreement and authorization, private modification of device may result in the 

electromagnetic compatibility problem of that device or other devices.

2) The design and test of Melting and Filling Gun complies with the related operation regulations 

of electromagnetic compatibility.

13. Beyes Limited Warranty Statement

13.1 SCOPE OF WARRANTY

BEYES Dental Canada Inc. warrants to the original retail purchaser that it will be at BEYES 

option to repair or replace components of the dental products manufactured by BEYES (except 

for components not warranted under 'Exclusions') that are defective in material or workmanship 

under normal use and service. BEYES’ obligation under this limited warranty is limited to the 

repair or replacement of the applicable components. This limited warranty shall only apply to 

defects that are reported to BEYES within the applicable warranty period and which, upon 

examination by Beyes, prove to be defective. This warranty extends only to the first retail 

purchaser of a product and is not transferable or assignable. Replacement components or 

products may be used and/or refurbished components or products, provided they are of like 

quality and specifications as new components or products.

13.2 APPLICABLE WARRANTY PERIOD

The applicable warranty period, measured from the date of invoice to the original user, shall be 

as follows Gpro P1 are warranted for a period of 12 months

13.3 EXCLUSIONS

This limited warranty does not cover and BEYES shall not be liable for the following;

1) Defects, damage or other conditions caused, in whole or in part, by misuse, abuse, 

negligence, alteration, accident, freight damage, negligent storage, tampering or failure to seek 

and obtain repair or replacement in a timely manner; 

2) Products which are not installed, used, and properly cleaned and maintained as required 

or recommended in the BEYES 'Installation' and/or 'Installation/Operation Manual' for the 

applicable product, including the specified structural and operational environment conditions 

and electrical power requirements;

3) Products considered to be of a consumable or sterile nature;

4) Accessories or parts not manufactured by BEYES;

5) Charges by anyone for adjustments, repairs, replacement parts, installation or other work 

performed upon or in connection with such products which are not expressly authorized in 

writing in advance by BEYES;

6) Costs and expenses of routine maintenance and cleaning;

7) Representations and warranties made by any person or entity other than BEYES;

8) Matching of color, grain or texture except to commercially acceptable standards;

Содержание GPRO P1

Страница 1: ...Gutta Percha Obturation System Instruction for Use...

Страница 2: ...k involved safety requirements are classed under the following indications Danger Always refer to personal injury Warning Refer to possible damage to property Table of Contents 1 Introduction 3 2 Inst...

Страница 3: ...nded Use It is used to heat cut soften and downpack gutta percha to obturate root canals in endodontic treatment 1 3 Contraindications Patient allergic to known natural latex and metals such as stainl...

Страница 4: ...And the design of left and right sides are perfectly symmetrical which enables either left hand or right hand operation 1 ON OFF button 2 Heating button 3 Heat insulation sleeve 4 Tip 5 Connecting ho...

Страница 5: ...e first use Warning Do not drain battery Always charge to full to maintain battery life Recharge battery if the device has not been used for more than 1 month 2 Installation 2 1 Charge device 1 Instal...

Страница 6: ...nto heating chamber completely Note To remove the tip hold near the turn of the tip and gently pull out Warning Needle remains hot after use Wait till display 0 C Warning Before each use clean disinfe...

Страница 7: ...release on off button to select the temperature setting Temperature setting cycles as shown below Note The display shows 0 C when no button is pressed If the tip heats up or cools down the display sho...

Страница 8: ...oint 4 7 mm short of the working length Move and set the endo stop accordingly 6 Insert the selected master Gutta Percha cone that is coated with sealer 7 Insert GPro P1 tip in the orifice of the cana...

Страница 9: ...ower adapter Optional preset temperatures 150 C 180 C 200 C 230 C Time consumption for charging About 2 5h First charging needs 3 h Power supply Input AC100V 240V 50 60Hz 800mA Output DC15V 1 6A Batte...

Страница 10: ...tch Ordinary equipment Used indoor only Device complies with WEEE directive Can be autoclaved Keep dry Handle with care Recovery Attention Please refer to the accompanying documents Humidity limit for...

Страница 11: ...should be equipped with adequate protection such as goggles mask etc to prevent cross infection 7 The product should be in strict accordance with relevant operation specifications of medical authority...

Страница 12: ...le and diffluent solvents for cleaning which will damage the surface of the device or cause the markings on the machine to fade 8 2 Daily maintenance 1 When the device is not used please turn off the...

Страница 13: ...s the interior of the heating chamber is fixed by the cooling of the gutta percha 1 Power on and set the temperature to 200 C After the temperature reaches the set value pull out the pushing ram back...

Страница 14: ...only to the first retail purchaser of a product and is not transferable or assignable Replacement components or products may be used and or refurbished components or products provided they are of lik...

Страница 15: ...arranty is the repair or replacement of defective parts Beyes shall not be liable for and hereby disclaims any direct special indirect incidental exemplary or consequential damages or delays including...

Страница 16: ...aplein 10 Ie Verd 2595AA The Hague Netherlands Tel 31645171879 English 31626669008 Dutch Email info beyes ca Website www beyes ca Printed in Canada ENI036 Rev 1 12 03 21 Federal law restricts this dev...

Отзывы: