background image

32

13.  WARRANTY

Lower 

leg

Resistance 

of the calf 

muscles

 

 

 

Foot

Training 

the foot

 

 

 

Shoul-

der

Resistance 

of the 

trapezoid

 

 

Abdo-

minal

Resis-

tance of 

abdominal 

muscles

 

 

 

Lumbar 

areas

Resis-

tance of 

the lower 

back

 

Fore-

arm

Extender 

of the 

wrist and 

Bender 

of the 

wrist and 

 

Hip

Resistance 

of the hip 

muscle

 

Thigh

Resistance 

of the 

hamstring 

muscle

 

  

Bewell Connect Corp.

Bewell Connect Corp.

Bewell Connect Corp

Bewell Connect 

-Corp.

Bewell Connect Corp.

 will repair or replace this product free of charge in the case of defective parts 

fa

or manu- cturing defects, in accordance with the conditions mentioned below as follows:
DURATION: 24 MONTHS RETURN TO WORKSHOP

-

voice, or another proof of purchase, with this guarantee card will be required to obtain an after-sales 
service, in accordance with this guarantee. This guarantee card will not be extended to another per-

-

including the user.
This guarantee covers only the defects of the material or parts, occurring during normal use of the 
pro-duct. It does not cover the damage caused during the transport of the apparatus, causes due 

equipment not approved by 

or causes con t

r ary to those written in the user 

manual or 
notice. Moreover, the present guarantee does not cover damage due to falls, bad handling, bad in-

cover the packing of the material, the accessories, the defects caused by commercial exposure of the 
product, show room, sale space, demonstration etc... Normal maintenance, cleaning and the replace-
ment of parts where wear is normal, are not covered by the terms of this guarantee. 

 and its  representatives and agents will not in any case be held responsible for any damage 

and consecutive  damages due to the mishandling of this product. This guarantee is the only valid one

 at 

, any other guarantee (commercial guarantee) except  this one will not be taken

nto account.

contact the 

 customer service.

31

Содержание Mytens BW-TSX

Страница 1: ...ser Manual 072015 1 1 BW TSX 0197 Manufacture Nexmed Technology Co LTD Address 2nd Floor of No 1 building Jia An Technological Industrial Park 67 District Bao An 518101 Shenzhen China BW TSX Web site...

Страница 2: ...e in case of anomalies or malfunction Electronic medical equipment requires special precautions regarding electromechanical com patibility It must be installed and used in accord with EMC ElectroMagne...

Страница 3: ...s Do not place the electrodes near cancerous lesions because this may have a negative impact on these injuries Do not place the electrodes on skin areas whose sensations are not normal You may burn yo...

Страница 4: ...ions Always consult your doctor or midwife if you are pregnant and intend to use the device cal muscle stimulation EMS device could in this case cause a blood clot In case of cognitive impairment If y...

Страница 5: ...Strengthening of the muscular mass EMS 8 standard programmes Stimulation of the venous return TENS Easy to use Data transfer onto a phone or a Bluetooth 4 0 tablet 4 USE 4 1 DE See schema in page 8 SC...

Страница 6: ...mage do not use the device or one of the electrodes Usable indoors and outdoors the device is not designed to withstand all weather conditions The device is not waterproof Do not wet it and never use...

Страница 7: ...angerous However if you experience discomfort it is advisable to decrease the intensity of the programme change or move the electrodes The burst transcuta neous electrical neurostimulation Burst TENS...

Страница 8: ...tion must remain comfortable and muscle contractions must not are advised to choose a low intensity to limit muscular fatigue SummaryTable of the EMS Programmes EMS Impulses Treatment site Name Treatm...

Страница 9: ...harge the device fully before beginning a session If the charge is not complete at the beginning of a programme the battery may become deplete before the end of the session You cannot use the device w...

Страница 10: ...g or biting sensation Note Always connect the device before you place the electrodes on the skin Note Do not place the electrodes on top of each other or so close to each other that they touch each ot...

Страница 11: ...ensity lever you want Starting and stopping a treatment Tap the play button on the screen The treatment screen opens and the time starts to count down The status indicator on the device starts to flas...

Страница 12: ...en stimulation is uncomfortable i e when you experience an unpleasant stinging or biting sensation Note Always replace the electrodes with electrodes recommended for this device by the manufacturer 5...

Страница 13: ...9mmx55 8mm Programmes 19 programmes 11 TENS 8 EMS programmes Battery 3 7V 500mAh Li lon Output voltage max 60mA 10 1000 load Conditions of use 5 C to 40 C with a relative humidity of 15 to 93 atmosph...

Страница 14: ...on electromagnetic IMMUNITY The customer or the user of these electrical stimulators should assure that it is used in such environment Immunity test IEC 60601 test level Compliance level Electromagnet...

Страница 15: ...ith the legal obligation For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequ...

Страница 16: ...Pain in the lower back Elbow Pain in the elbow Fore arm Pain in the forearm Wrist Pain in the wrist and carpal tunnel syndrome Hip Pain in the hip 12 Thigh Sciatic pain Knee Knee pain Lower leg Pain...

Страница 17: ...ard will not be extended to another per including the user This guarantee covers only the defects of the material or parts occurring during normal use of the pro duct It does not cover the damage caus...

Отзывы: