4.5. DOWNLOADING THE APPLICATION

Download the  application to your phone or tablet:
- by the App store or Google Play

Then click the 

My

Tens icon.

4.6. STARTING AND USING 
Preparation of the treatment areas and installation of the stimulator

1.  Before placing the electrodes, check that the skin does not show injury or redness and is 

healthy.

t

 Transcutaneous electrical neurostimulation (TENS) programmes : Do not position the elec-
trodes on irritated skin or skin with open wounds, rashes or cancerous lesions 

t

 Electrical muscle stimulation (EMS) programmes : Position the electrodes only on intact and 
healthy muscles. 

2.  Using a damp cloth, clean the skin and then dry it. To receive the electrodes, it must be clean 

and dry, without cream or lotion. Any oil, dust or other element that may be on the skin could 
prevent the electrodes from adhering. 

3.  Remove the electrodes from the bag, ensure they are not damaged or worn. If the expiry limit 

is exceeded, do not use these electrodes.

4. Pull the electrode off the liner, and attach the electrodes to the device using the pressure 

buttons provided for this purpose. 

5.  

See the section"PLACING THE ELECTRODES".

6.  Put the second electrode on the area of the body to treat (See the section

"PLACING THE ELECTRODES").  Avoid  any contact between the electrodes and not place one 
on the othe

Note:Replace the electrodes when they are damaged or dirty, when they have lost their 
adhesive power or when stimulation becomes uncomfortable, i.e. when you experience an 
unpleasant stinging or biting sensation.
Note

Always connect the device before you place the electrodes on the skin.

Note: Do not place the electrodes on top of each other or so close to each other that they 
touch each other.

r.  

 

Remarks

-  

under clothing.

- You can keep a device on the body, even between two sessions.
- It is possible that you may need external assistance for placing the electrodes in certain areas.

Locating the electrodes
Warning 

As indicated in “Do not treat the the following parts or areas” :
Do not place the electrodes on the head, carotid, on any side of the neck, at the front of the neck 
or on the torso. Do not position the electrodes on swollen skin or skin with open wounds, rashes 
or cancerous lesions or on irritated skin. 

skin. You are advised to place the electrodes at the level of the area to be treated or in the vici-
nity of this area.  Before installing the electrodes in a place, ensure you have good feeling in the 

-

rostimulation programmes), it is advisable to move the electrodes. If during electrical muscle 
stimulation programmes (intended especially to create a contraction of the muscle) no contrac-
tion occurs, this may mean an intensity too low or bad installation of the electrodes.

Starting a session through the use of the  application   

1.  Ensure that the Bluetooth (4.0) connection is activated on your smartphone or tablet. Open 

the application .  

 

2. 

 

 

Standby mode, ready for the session). The App detects the stimulator which is switched on. 

 

t

3. Open the BW-TSX device and your APP,and the indicator on your APP transform red to green in fig.
    3.1 below. And tap the       button to known the information about "TENS" and "EMS", and then tap 
    "OK" to continue, in fig.3.2 below.

o begin a session.

 

In  

fig.3.1

fig.3.2

Содержание Mytens BW-TSX

Страница 1: ...ser Manual 072015 1 1 BW TSX 0197 Manufacture Nexmed Technology Co LTD Address 2nd Floor of No 1 building Jia An Technological Industrial Park 67 District Bao An 518101 Shenzhen China BW TSX Web site...

Страница 2: ...e in case of anomalies or malfunction Electronic medical equipment requires special precautions regarding electromechanical com patibility It must be installed and used in accord with EMC ElectroMagne...

Страница 3: ...s Do not place the electrodes near cancerous lesions because this may have a negative impact on these injuries Do not place the electrodes on skin areas whose sensations are not normal You may burn yo...

Страница 4: ...ions Always consult your doctor or midwife if you are pregnant and intend to use the device cal muscle stimulation EMS device could in this case cause a blood clot In case of cognitive impairment If y...

Страница 5: ...Strengthening of the muscular mass EMS 8 standard programmes Stimulation of the venous return TENS Easy to use Data transfer onto a phone or a Bluetooth 4 0 tablet 4 USE 4 1 DE See schema in page 8 SC...

Страница 6: ...mage do not use the device or one of the electrodes Usable indoors and outdoors the device is not designed to withstand all weather conditions The device is not waterproof Do not wet it and never use...

Страница 7: ...angerous However if you experience discomfort it is advisable to decrease the intensity of the programme change or move the electrodes The burst transcuta neous electrical neurostimulation Burst TENS...

Страница 8: ...tion must remain comfortable and muscle contractions must not are advised to choose a low intensity to limit muscular fatigue SummaryTable of the EMS Programmes EMS Impulses Treatment site Name Treatm...

Страница 9: ...harge the device fully before beginning a session If the charge is not complete at the beginning of a programme the battery may become deplete before the end of the session You cannot use the device w...

Страница 10: ...g or biting sensation Note Always connect the device before you place the electrodes on the skin Note Do not place the electrodes on top of each other or so close to each other that they touch each ot...

Страница 11: ...ensity lever you want Starting and stopping a treatment Tap the play button on the screen The treatment screen opens and the time starts to count down The status indicator on the device starts to flas...

Страница 12: ...en stimulation is uncomfortable i e when you experience an unpleasant stinging or biting sensation Note Always replace the electrodes with electrodes recommended for this device by the manufacturer 5...

Страница 13: ...9mmx55 8mm Programmes 19 programmes 11 TENS 8 EMS programmes Battery 3 7V 500mAh Li lon Output voltage max 60mA 10 1000 load Conditions of use 5 C to 40 C with a relative humidity of 15 to 93 atmosph...

Страница 14: ...on electromagnetic IMMUNITY The customer or the user of these electrical stimulators should assure that it is used in such environment Immunity test IEC 60601 test level Compliance level Electromagnet...

Страница 15: ...ith the legal obligation For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequ...

Страница 16: ...Pain in the lower back Elbow Pain in the elbow Fore arm Pain in the forearm Wrist Pain in the wrist and carpal tunnel syndrome Hip Pain in the hip 12 Thigh Sciatic pain Knee Knee pain Lower leg Pain...

Страница 17: ...ard will not be extended to another per including the user This guarantee covers only the defects of the material or parts occurring during normal use of the pro duct It does not cover the damage caus...

Отзывы: