9. Troubleshooting
Error display Possible causes of errors
Correction of errors
“0-Ld”
The maximum capacity of 441 lb (200 kg,
31 st : 7 lb) has been exceeded.
Weigh only the maximum permissible
weight.
“Err”
The electrical resistance between the conduc-
tors and the soles of the feet is too high (e.g.
in the case of thick calluses or too dry soles).
Repeat the measurement barefoot.
If necessary, remove the calluses from the
soles of your feet.
The fat percentage is outside the measurable
range (less than 5 % or greater than 65 %).
Repeat the measurement barefoot.
If necessary, remove the calluses from the
soles of your feet.
The water percentage is outside the
measurable range (less than 25 % or greater
than 75 %).
Repeat the measurement barefoot.
If necessary, remove the calluses from the
soles of your feet.
The muscle percentage is outside the measur-
able range (age and gender related).
Repeat the measurement barefoot.
If necessary, remove the calluses from the
soles of your feet.
“Lo”
Low Power.
Change the battery.
No display.
Battery is empty, battery was inserted
incorrectly or the scale is broken.
Scale shows unrealistic results.
Wait until scale switches off automatically.
Repeat measurement.
Place the scale on level flooring (no carpet).
Don’t move during weighing.
10. Cleaning, maintenance and disposal
• Clean the scale occasionally with a damp cloth.
• Do not use aggressive cleaning agents and never submerge the scale. The unit is not waterproof. Do not
immerse the unit in water and do not spill water over the unit. If your scale accidentally gets wet immediately
dry it.
• Store the unit in a safe and dry location. Do not expose the unit to direct sunlight, extreme hot or cold tem-
peratures or humidity. Thoroughly dry any moisture off the unit before storing. Store the unit safely out of the
reach of children. Do not subject the unit to strong shocks, such as dropping the unit on the floor. Always fol-
low the instructions provided in this manual.
Disposal
Observe the local regulations for material disposal. Dispose of the device in accordance with local
regulations. If you have any questions, please contact the local authorities responsible for waste disposal.
11. Technical specifications
Battery type
4 x 1.5 V batteries AAA
Measuring range
4.4 lb to 441 lb (2 kg to 200 kg, 0st : 4lb to 31st : 7lb)
Weight unit
0.2 lb/100 g/0.01 st
Body fat, water, muscle percentage unit 0.1%
Electrical current of B.I.A.
5 μA / 1V max
Fat percentage range
5 % to 65 %
Water percentage range
25 % to 75 %
Muscle percentage range
25 % to 80 %
Temperature operating range
41 °F to 95 °F (5 °C to 35 °C)
Storage temperature range
-4 °F to 140 °F (-20 °C to 60 °C)
Subject to technical modifications.