97
ALTITUDE SENSING AND ADJUSTMENT
Prior to the first dive of a series of repetitive dives, Altitude (i.e., Ambient Pressure) is mea-
sured upon activation and every 15 minutes until a dive is made.
> While it is operating in Surface mode after a dive, measurements are taken every 15
minutes during the 24 hour period after surfacing.
> Measurements are only taken when the unit is dry.
> Two readings are taken, the second reading 5 seconds after the first. The readings
must be within 30 cm (1 foot) of each other to record that ambient pressure as the
current Altitude.
The mathematical model in the VOYAGER 2G accounts for the reduced No Deco Dive
Times available based on National Oceanic and Atmospheric Administration (NOAA)
guidelines.
When diving in high altitude waters from 916 to 4270 meters (3001 to 14000 feet), the
VOYAGER 2G automatically adjusts to these conditions providing corrected Depth, re-
duced No Deco Dive Times, and reduced Oxygen Accumulation Times at Altitude intervals
of 305 meters (1000 feet).
No adjustments are made during any time that the Wet Contacts are wet.
At an elevation of 916 meters (3001 feet), Depth Calibration automatically changes from
feet of seawater to feet of fresh water. This is the first adjustment to the Algorithm.
Содержание VOYAGER-2G
Страница 1: ......
Страница 7: ...7 OVERVIEW...
Страница 15: ...15 FEATURES AND DISPLAYS...
Страница 21: ...21 SURFACE MODES...
Страница 45: ...45 NORM DIVE MODES...
Страница 53: ...53 CAUTIONARY MODES...
Страница 65: ...65 SWITCHING GAS MIXES...
Страница 69: ...69 NORM POST DIVE MODES...
Страница 73: ...73 GAUGE OPERATING MODE...
Страница 77: ...77 FREE DIVE OPERATING MODE...
Страница 89: ...89 GENERAL...
Страница 106: ...2002 Design 2010 Doc No 12 27925 r01 7 12 10...