63
Fig. 69 - PO2 ALARM MAIN
(Deco)
High PO2 during Deco
(Fig. 69)
The PO2 Alarm setting does not apply when in Deco.
> If PO2 reaches 1,60 while at a Deco Stop, the PO2 value
(1,60) with graphic will alternate with Deco Stop Depth/
Time and Elapsed Dive Time once each minute*.
*PO2 flashing for 10 seconds, Deco Stop Depth/Time on for 50 seconds until
PO2 decreases below 1,60 , then Deco only (no PO2).
HIGH O2 (NORM only)
Warning >> at 80 to 99% (=> 240 OTU).
Alarm >> at 100% (= 300 OTU).
When O2 increases to the Warning Level; the audible will
sound, and the O2 icon will appear flashing (Fig. 70) until O2
decreases below 80% after surfacing or by a gas switch.
If O2 reaches the Alarm level; the audible will sound during
which the full O2BG will flash, the graphic UP will flash in ad-
dition to the O2 icon (Fig. 71) until O2 decreases below 100%
after surfacing or by a gas switch.
• S (< 2 sec) - to acknowledge/silence alarms.
• S (2 sec) - to activate the Backlight.
• A (< 2 sec) - to access ALTs (similar to No Deco or Deco).
• M (2 sec) - to access Gas Switching.
Fig. 70 - HIGH O2 WARNING
Fig. 71 - HIGH O2 ALARM
(during audible)
Содержание VOYAGER-2G
Страница 1: ......
Страница 7: ...7 OVERVIEW...
Страница 15: ...15 FEATURES AND DISPLAYS...
Страница 21: ...21 SURFACE MODES...
Страница 45: ...45 NORM DIVE MODES...
Страница 53: ...53 CAUTIONARY MODES...
Страница 65: ...65 SWITCHING GAS MIXES...
Страница 69: ...69 NORM POST DIVE MODES...
Страница 73: ...73 GAUGE OPERATING MODE...
Страница 77: ...77 FREE DIVE OPERATING MODE...
Страница 89: ...89 GENERAL...
Страница 106: ...2002 Design 2010 Doc No 12 27925 r01 7 12 10...