Upon entry into the following Violation modes, the Audible will sound,
even if set Off. When these events occur, the alarm cannot be acknowl-
edged/silenced by pressing S.
DELAYED VIOLATION 1 (DV1)
If you remain above a required Deco Stop Depth more than 5
minutes, operation will enter DV1 which is a continuation of CV.
The audible will sound for 10 seconds, and the full NBG will
flash until you descend below the required Stop Depth.
DV1 Main,
information includes (Fig. 62) -
> Altitude (mountain) icon, only if EL 2 to 7.
> Current Depth with M (or FT) icon.
> Stop Depth (M or FT), with STOP icon (flashing).
> Ascent Rate (MPM or FPM) with - ASC - icon, if ascending.
> Stop Time (hr:min) with DEC icon (flashing) and clock (time)
icon.
> Gas 1 (or 2) icon, one in use.
> Full NBG (flashing); and O2BG, ASC - if applicable.
• A (< 2 sec) - to access ALTs 1, 2, 3 (similar to Deco).
• S (2 sec) - to activate the Backlight.
• M (2 sec) - to access Gas Switch Preview.
Fig. 62 - DV1 MAIN