Aftercare
Aftercare
In the event that your product has a problem some maintenance may be
required.
Dripping head, hand shower or body jets when mixer OFF
Some dripping may occur after the mixer is turned off, this is expected
due to drainage.
If the dripping does not stop, this may be due to debris on the valve
sealing surface, within the cartridge or a fault.
To remove the valve:
TURN OFF WATER SUPPLY
Turn the diverter to an open position to allow water to drain.
On the handle unscrew the handle peg (Fig 1).
Using a hex key, loosen the grub screw inside the handle (Fig 2).
Pull off the handle.
Using a spanner remove the brass retainer (Fig 3)
Pull the cartridge from the mixer housing (Fig 4)
Check the internal mixer base and clear any debris.
Flush the cartridge under running water while turning spindle.
Once maintenance is carried out replace the cartridge.
Ensure to align the two pegs on the base of the cartridge with the
two smaller holes inside the mixer (Fig 5).
Re-fit all components.
Turn on water supply and re-check.
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5