17
•
Select the required parameters and press the key. The cycle will start, and end after the set time
has elapsed.
To go back to the main menu, press the key.
PETROL injectors
• Use the arrows to select the duration of the cycle (1-60 min.) timer (total duration of cleaning cycle).
Then press the key.
• Use the arrows to select the injector opening time (5-10 ms) (control time required to open the
injector).
Then press the key.
• Use the arrows to select the impulse frequency (1-10 Hz) (number of times the injector is controlled
in one second).
Then press the key.
•
Select the required parameters and press the key. The cycle will start, and end after the set time
has elapsed.
To go back to the main menu, press the key.
ISTRUZIONI PER L’USO
I
INSTRUCTIONS FOR USE
EN
STEP 1
PETROL INJIECTOR
TIMER
60
min
STEP 2
PETROL INJIECTOR
OPENING TIME 5 ms
STEP 3
OPENING TIME 5 ms
PETROL INJIECTOR
PULSE FREQ.
10
hz