NB: If the components are worked on for a prolonged time, in case of certain deposits, or should
an excessively aggressive detergent be used, the component may stop irremediably due to poor
lubrication.
SETTING CONTROL PROGRAMME:
LPG injectors
• Use the arrows to select the duration of the cycle (1-60 min.) timer (total duration of cleaning
cycle).
Then press the key.
• Use the arrows to select the injector opening time (5-10 ms) (control time required to open the
injector).
Then press the key.
• Use the arrows to select the impulse frequency (1-10 Hz) (number of times the injector is controlled
in one second).
Then press the key.
LGP INJIECTOR
PETROL INJIECTOR
PWM DEVICES
STEP 1
STEP 2
STEP 3
LGP INJIECTOR
LGP INJIECTOR
OPENING TIME 5 ms
LGP INJIECTOR
OPENING TIME 5 ms
TIMER
60
min
PULSE FREQ.
10
hz