background image

TQ-22

Mixer Reference

manual

- I -

UG-TQ22-EN (V2.2-211226)

Symbols used in this Manual

The following symbols are used for explanations on limiting, warning and prompt in

operation and instructions so as to ensure safety:

" Warning! "

is the term denoting the instructions on relevant personal safely. Failure to

follow these instructions may result in personal casualty.

" Caution! "

is the term denoting the instructions on damages that may be caused to the

relevant devices. Failure to follow these instructions may result in equipment damage
and this damage is not within the range of quality guarantee.

Important Safety Information

In order to prevent fire or electric shock, please do not expose this equipment in the rain or

a damp environment. The max. working environmental temperature is 40

, please do not

insert power source in the unwatched condition. Please make sure to pull out the power

plug immediately after completing the use.

Please do not use the power source with the voltage and frequency not in conformity with

those indicated on the machine, use of different ones may cause a fire or an electric shock.

Please do not scrape, damage or alter the power cord nor place any heavy objects on the

power cord, do not pull or over-bend the power cord.

Lay the power cord at places far away from the heat, or otherwise the skin of the power

cord will be softened and may cause a fire or an electric shock.

Please do not use the power cord whose electric contact at any of its ends is found with the

sign of corrosion or overheat, nor any power cord that it seems damaged in any way, as the

damaged power cord may cause a fire or an electric shock.

Make sure to use the power supply, outlet and power cord with protective grounding, so
as to maintain the equipment in good protective grounding.

Immediately turn off the power switch and unplug the power plug from the receptacle when

the machine falls off or gets damaged in any way.

Please do not make bold to open the cabinet and repair or reconstruct the machine, the

high voltage and sharp components inside the machine may hurt you.

Clean the machine with a piece of wiping cloth dipped with mild detergent and water and

fully dried. Please do not use alcohol, paint thinner or other inflammable substances such

as gasoline, nitrocellulose lacquer thinner etc.

The purpose of the excalmatory mark in an equilateral triangle is to
remind the user of paying attention to the important safety, operation
and maintenance instructions existing in the Manual.

The arrow headed lightning symbol in the triangle is to remind the
user of the un-insulated "dangerous" voltage that exists in the product
housing and may constitute an electric shock risk to the human body.

Содержание TQ-22

Страница 1: ...TQ 22 DIGITAL LIVE SOUND CONSOLE Applicable to Firmware Version 2 2 Reference manual Digital mixer...

Страница 2: ...UG TQ22 EN V2 2 211226 TQ 22 Mixer Reference manual...

Страница 3: ...ion and maintenance of this product Please make sure to firstly read the Important Safety Information on page I of this Manual Revision history Revision Revision description and content updated V1 0 I...

Страница 4: ...the power cord at places far away from the heat or otherwise the skin of the power cord will be softened and may cause a fire or an electric shock Please do not use the power cord whose electric cont...

Страница 5: ...nerated in special installation conditions If the machine indeed brings harmful interference to radio or television reception can be determined by turn on or turn off the machine users are encouraged...

Страница 6: ...TQ 22 Mixer Reference manual Packing content of TQ 22 Mixer TQ 22 Main Unit Not including tablet 1pcs AC power cord 1pcs WIFI wireless adapter USB interface 1pcs Bluetooth adapter USB interface 1pcs U...

Страница 7: ...Monitor headphone 9 1 7 Restrictions on USB interface power 9 Chapter 2 Detailed Description of TQ 22 10 2 1 Input Channels 11 2 1 1 Home of the input channels 11 2 1 2 Overview of input channels 12 2...

Страница 8: ...Bluetooth playback 38 2 6 Grouping shortcuts 39 2 6 1 DCA volume grouping 39 2 6 2 Mute Groups 41 2 7 User defined fader 42 2 8 SCENES 43 2 9 System settings 44 2 9 1 Automatic microphone mixing cont...

Страница 9: ...tuning fun easily and contentedly Download the latest available firmware version of TQ 22 install The latest functions for your mixer or optimize and upgrade the performance Timely receive the latest...

Страница 10: ...quency Equalizer GEQ 4 band parametric frequency Equalizer PEQ including high shelf filter HSF low shelf filter LSF high pass filter HPF low pass filter LPF Configuration 4 professional DSP effectors...

Страница 11: ...ew scenes when needed Automix can be set on AUX1 8 and the input channels include microphones from CH01 to CH16 channels It has intelligent algorithms for weight distribution and gain sharing ISUeasyT...

Страница 12: ...ric fader 03 Motorized faders Used to adjust the volume or gain 04 Mute the channel or mute the route In GEQ it is used to zero the gain of the current frequency 05 Monitor button 06 Channel selection...

Страница 13: ...the current input channel Current input channel level meter The phantom power indicator and polarity indicator are on to indicate that it is valid 15 Gate Attack start time Release release time Thres...

Страница 14: ...gle channel differential balanced output XLR male interface 05 Bus output Main L R single channel differential balanced output XLR male interface 06 Expansion interface reserved 07 AC power input inte...

Страница 15: ...ct the input level or even lead to dramatically decay of input signal 4 Same way to setup other input channels single click other can setup other channels or you can use Copy to function to paste the...

Страница 16: ...ny time and all the parameters of the TQ 22 digital mixer can be set as the value of the scene TQ 22 digital mixer includes a lot of preset scenes to be used in all kinds of performance occasions In a...

Страница 17: ...he mixer it will produce interference Use the phone comes with the charger from other places to take power and the phone as the input source of the mixer will not be a problem 01 Rotate the headphone...

Страница 18: ...Channel meter inactive Disabled channel Noise indication invalid Compressor meter invalid DCA channel Status DCA channel Channel icon DCA specific icon DCA Channel color user defined Channel No DCA01...

Страница 19: ...and then adjust the knob on the panel 05 SOLO monitor switch 06 Channel gain Changed by fader adjustment 07 Channel linking indicator This indicator lights up when two adjacent channels are linked 08...

Страница 20: ...as the same function as the button on the panel 04 Home button click to return to the channel home page 06 Click to switch to the noise gate control page 05 Click to switch to the PEQ control page 08...

Страница 21: ...d then output the effect from AUX5 The steps are 1 Select the input channel where CH02 is located and click the button of channel CH02 to enter the edit page 2 Click any button of the bus button to sw...

Страница 22: ...nd gain The dotted circle represents the current frequency band the right list shows the parameters click or slide to select the parameter to be adjusted displayed as green text when selected you can...

Страница 23: ...he copy control page 07 Click to switch to the compressor control page 10 Click to switch to the channel setting page 09 Click to switch to the parameter preset page 12 The starting point for setting...

Страница 24: ...or control page 10 Click to switch to the channel setting page 09 Click to switch to the parameter preset page 12 Threshold which sets the starting point for the limiter to start attenuating the signa...

Страница 25: ...he button on the panel 04 Home button click to return to the channel home page 06 Click to switch to the noise gate control page 05 Click to switch to the PEQ control page 08 Click to switch to the co...

Страница 26: ...ck to enter scene control page save or load the scene parameters you need It has the same function as the button on the panel 04 Home button click to return to the channel home page 06 Click to switch...

Страница 27: ...ameter preset page 12 Channel name icon color user can choose or set Click to enter the setting interface see the next page for details 11 Click to switch to the channel overview page 13 Link the two...

Страница 28: ...l name Click this area to manually enter the channel name The maximum is 8 English characters 03 Preset common channel name click to quickly select the channel name 04 Preset common channel icon click...

Страница 29: ...ff 06 Channel linking icon when the adjacent two mono channels linked into a stereo channel the logo lights 05 Channel gain Changed by fader adjustment unit dB 07 The compressor icon lights up to indi...

Страница 30: ...04 Home button click to return to the channel home page 06 Click to switch to the GEQ control page 05 Click to switch to the PEQ control page 08 Click to switch to the copy to control page 07 Click t...

Страница 31: ...to switch to the GEQ control page 05 Click to switch to the PEQ control page 08 Click to switch to the copy to control page 07 Click to switch to the compressor control page 10 Switch to the channel c...

Страница 32: ...4 Home button click to return to the channel home page 06 Click to switch to the GEQ control page 05 Click to switch to the PEQ control page 08 Click to switch to the copy to control page 07 Click to...

Страница 33: ...to the copy to control page 07 Click to switch to the compressor control page 10 Click to switch to the channel configuration page 09 Click to switch to the parameter preset page 11 Click to switch t...

Страница 34: ...age Same function as the button on the panel 03 Scene button click to enter scene control page save or load the scene parameters you need It has the same function as the button on the panel 04 Home bu...

Страница 35: ...s displayed in brown and the TFT guide screen is also displayed in brown The color of channels that cannot be routed is not changed Step 3 Use the navigation bar 01 to select the group where the input...

Страница 36: ...before the fader AUX4 wants to have all the processing and is controlled by the input channel volume and DCA then the access point is selected as Pst fdr after the fader The above is just an example E...

Страница 37: ...parameter value and the system automatically measures two neighboring time you hit the button NOTE This operation can also be performed without the FX settings menu Only FX1 and FX2 have TAP function...

Страница 38: ...to enter scene control page save or load the scene parameters you need It has the same function as the button on the panel 04 Mute switch The FX channel route is muted when red is lit and no signal is...

Страница 39: ...control page Set the high low shelf filter for the effect 03 Switch to the FX setting menu 04 Switch to the channel parameter copy pages you can copy parameters of current channel to another channel...

Страница 40: ...the amount of feedback Scaler Echo gain 2 4 6 Flanger effect Flanger effect can be used to create special effects such as short time delay chorus tremolo etc Frequency Modulation frequency Quick modul...

Страница 41: ...riginal pitch Feedback The feedback of output delay signal to the input end Delay Basic delay unit ms RandDelay Random delay unit ms ModFreq The rate of random delay is affected and the decay quantity...

Страница 42: ...sent out from the left and right channels through the different decay of the left and right channels like ping pong s motion trail effect Delay Create an effect of a sound that moves back and forth T...

Страница 43: ...pages you can copy parameters of current channel to another channel effect 05 Switch to the FX preset parameter management page you can retrieve the pre saved effect parameters eliminating the troubl...

Страница 44: ...rol menu 06 Click to switch to the Bluetooth playback menu 07 Click to open the preset management page 08 Click to switch to the channel configuration page 09 Click to switch to the channel overview p...

Страница 45: ...nnel overview page 03 Click to switch to the PEQ control menu 04 Click to switch to the USB playback menu 05 Click to switch to the USB recording control menu 06 Click to switch to the Bluetooth playb...

Страница 46: ...same time 01 Click the USB group on the navigation bar to switch to the home page and then click the channel label to enter the USB menu As shown above 02 Home button click to return to the home page...

Страница 47: ...the button on the panel to quickly switch to the DCA overview page as shown below Operate the button of 02 or click the button on the panel to achieve one key group mute The fader or motorized fader o...

Страница 48: ...CA settings menu as shown below 01 DCA group number 02 DCA mute switch The red light indicates mute All pre associated channels will be synchronized with one button mute 03 Input and output channels t...

Страница 49: ...output channels will be muted In the system parameter setup menu you can set the mute group as follows Quick Setup Press and hold the mute group button for a long time more than 1 second and then cli...

Страница 50: ...ick any fader page button to exit the custom editing menu SKILLS 1 On the main screen use your finger to press and drag the corresponding channel to the custom fader channel and then release to comple...

Страница 51: ...to the home menu 02 Save all current parameters as user scenes according to the specified path and scene name 03 The name of the scene currently in use 04 User defined scene preset library placed ins...

Страница 52: ...to enter the system upgrade menu 05 Click to enter the permission control management menu 06 Click to clear all mute settings including channel mute and mute grouping Click DCA to clear the DCA s mut...

Страница 53: ...mixing channel and the channel that does not participate in the automatic mixing 05 Select the output bus for the automix feature 04 Auto mix on off 07 Input channel label 06 The bus name of the curre...

Страница 54: ...commissioning calibration and external devices for the mixer 01 Return to the home page 02 Set the frequency of the sine wave from 20Hz to 20kHz 03 Select the signal type sine wave white noise pink n...

Страница 55: ...eration authority control Authorization control is used for hierarchical management of operators 01 Return to the system parameter setting menu 02 Click Enter Password 03 Current user name click to en...

Страница 56: ...evice information mainly provides the hardware version software version IP address and production date of the mixer which is convenient for future maintenance work 01 Return to the system parameter se...

Страница 57: ...ing conditions 3 Enter the system settings menu Click Upgrade on the screen Start the firmware upgrade program ISUeasy TM Read the precautions carefully and confirm that it is correct Click Continue t...

Страница 58: ...iPad 5 Run the app When the WIFI flag on the APP turns green it means that the APP has established a communication connection with the TQ 22 digital mixer and now it can be remotely operated Android t...

Страница 59: ...e machine is still working normally the parameters and status are frozen unchanged all faders buttons shuttles and touch screens are forbidden to operate The channel guide screen displays as usual and...

Страница 60: ...ll mixer parameters from the internal and U disk to mixer Channel presets User channel presets can be saved or recalled from the internal and U disk to mixer Scene mode 6 quick scene quick buttons can...

Страница 61: ...inimum input level of output 4dBu 1 23V can be generated when the mixer is set to the maximum gain all faders and level controllers are at the maximum position Output channel gain is 0dB Analog port i...

Страница 62: ...TQ 22 Mixer Reference manual 54 UG TQ22 EN V2 2 211226 Appendix 2 The Mixer Block Diagram...

Страница 63: ...55 UG TQ22 EN V2 2 211226 TQ 22 Mixer Reference manual Appendix 3 Dimensions 553mm 550mm 206mm 61mm...

Страница 64: ...guan 3G Audio Technology Co Ltd Add Building 3 No 1 Nanqi street Qiaodong road Qiaotou town Dongguan City Guangdong province 523800 China Website www beta3pro com MIX TQ 22 Showing rich sound connotat...

Отзывы: