8
CHECK THE SUFFICIENT GROUND CONNECTION OF THE WORKPIECE
BEFORE BEGINNING THE WELDING. THE MANUFACTURER IS NOT
RESPONSIBLE FROM CONSEQUENCES RESULTING FROM AN ABSENCE
OF GROUND CONNECTION NOR INSUFFICIENT OR INCORRECT GROUND
CONNECTION.
THE WELDED WORKPIECE MUST NOT TRANSFER HEAT TO THE TABLE
PLATE. THIS IS TO PREVENT DAMAGES FROM OCCURRING TO THE
MACHINE BEARING DUE TO THE THERMAL EXPANSION.
WELDING DIRECTLY TO THE TABLEP LATE IS STRICTLY PROHIBITED!
THE WELDING POSITIONER MUST BE CONNECTED TO A PLUG THAT
CONTAINS RESIDUAL-CURRENT DEVICE!
COMPLY WITH USER MANUAL AND LOAD CHART WITHIN THE MACHINE.
CAREFULLY GET TO KNOW THE LOAD CALCULATION PRACTICES.
1. Place the welding positioner on an even and sustainable ground that is
constructed from unbreakable concrete, whose material strength is 30 N / mm²
minimum.
2. Make sure that there is a sufficient working space around the machine. Also
notify the shapes and dimensions of the workpieces; the handling are of the
workpiece must be free from objects.
3. Get to know the technical data and performance regarding the machine, and
comply with them. Check the weight of the workpiece and its` centre of mass in
relation to the machine`s rotation and tilting axis (see the calculation instructions
and load chart).
4. Make sure that there is a free access to the work spot.
5. Connect the remote control cable to the connector in main central. Before
connecting, check that the main switch is in 0-position.
6. Check that the EMERGECY SWITCH-OFF –button in the remote control is
pressed down.
7. Connect the machine to an electrical grid.
•
240/400 V 3-phase 16 A
8. Turn the power on from the main switch of the machine.