Installation Instructions for Wi-Q Technology™ EXQ Exit Hardware Trim
BEST
a Product Group of dormakaba USA Inc.
13
Installation Instructions for Wi-Q Technology™ EXQ Exit Hardware Trim
Installing the exit hardware and trim
For mortise exit device installations
(mortise cylinder)
1
For doors less than 2
″
in thickness
, place the cylin-
der ring provided on the cylinder.
2 Rotate the cylinder cam to the 12 o’clock position, as
shown in Figure 21.
3 Using a cylinder wrench (ED211), insert the cylinder
through the cylinder opening in the escutcheon and
screw the cylinder into the mortise case. Make sure
that the figure-8 hole is in the 12 o’clock position.
Caution:
Do not screw the cylinder in too tightly.
Doing so may cause users to be locked out.
12
Install exit hardware and
secure escutcheon
For Precision 2200, 2700 and 2800 exit devices only
■
Drill a 5/16” hole through the front part of the chassis
as shown in Figure 22. (This hole is used to pass the
sensor harness and door position switch wires into the
chassis area.)
For all exit devices
1 Make any adjustments to the exit hardware necessary
for compatibility with lever function outside trim.
2 Install the exit hardware (lock stile case, touch bar
assembly, latches and rods [if applicable], and related
hardware); follow the instructions provided by the exit
hardware manufacturer.
Note:
The escutcheon is secured on the outside of the
door by the screws used to mount the lock stile case on
the inside of the door.
Caution:
When securing the escutcheon, make
sure that it does not pinch any wires.
Figure 20 Rim cylinder components
Rim
cylinder
Screws
Spindle
Clamp plate
Orient the curve
toward the cylinder.
Figure 21 Mortise cylinder components
Mortise cylinder
Cam in 12 o’clock
position
View of the back
of the cylinder
Figure 22 Drilling 5/16” hole for Precision 2200, 2700,
and 2800 exit devices only
Drill 5/16”
hole thru the
face of the
chassis here.
Drill ONLY
for 2200,
2700 and
2800 devices