"Besantek BST-CBF01" - Устройство для тестирования батарей. Инструкция по эксплуатации доступна для бесплатного скачивания с нашего manualshive.com. Научитесь пользоваться этим девайсом, загрузите руководство сейчас!
-
BESANTEK
BST-CBF01
FUSE, CIRCUIT BREAKER
and FAULT FINDER
� I ,,. I
""'
.i•tst-
"'"'"'
t1',4, .. !U4JTTE�
.
...
..
·
•
INSTRUCTION MANUAL
Страница 1: ... BESANTEK BST CBF01 FUSE CIRCUIT BREAKER and FAULT FINDER I I i tst t1 4 U4JTTE INSTRUCTION MANUAL ...
Страница 2: ...13 Very important features 14 Principle of How it work Display Results 15 Display Bar Graph 16 Automatic Battery test 17 Auto Off 18 Preparation for Use 19 Replacing the battery 20 Disposing of Battery 21 Specifications 22 Environmental 23 Cleaning 24 Limited Warranty Page 1 2 2 3 3 4 4 5 6 7 7 9 9 10 10 12 12 12 13 13 14 14 15 16 16 17 18 18 18 18 19 19 20 20 20 21 21 21 22 23 99 Washington Stree...
Страница 3: ...he power network connected to the station being measured In the event that lightning occurs stop all testing and isolate any temporarily installed test spikes Preparations for testing of power system grounding can leave personnel vulnerable to exposure caused by faults at or fed from the system under test transferred potentials from remote test grounds and inadvertent line energisations While the ...
Страница 4: ...ns before attempting to use this tester 2 Safety Check Before using the tester check the condition of the test leads the fuses and general appearance The leads must be free of cracks or any damages and must be insulated as when they were new Fuse replacement is described later in this user s manual When changing the fuse of the transmitter by removing the cover to access the internal circuitry alw...
Страница 5: ...age before touching it Do not use cracked of broken test leads THIS INSTRUMENT SHOULD ONLY BE USED BY A COMPETENT SUITABLY TRAINED PERSON REMEMBER SAFETY IS NO ACCIDENT CAUTION RISK OF ELECTRIC SHOCK CAUTION READ THE MANUAL 3 General Description It is a Fuse and Fault Finder which comprises of two parts The Receiver Rx and the Transmitter Tx Rx Tx 3 ...
Страница 6: ...e amplitude of the received signal is shown on a bar graph type Leds The more Leds ON the stronger the signal The Receiver uses one 9V battery 4 Product Description Transmitter The Transmitter connects to the mains socket or fault circuit which need to be traced To work correctly the socket or Circuit to be traced need to be powered or be live The connection is simple and use the plug Should you w...
Страница 7: ...ted to the Tx Once the Red Led Lit the Tx should generate The 10kHz signal current into wire or the circuit to trace Should the light not lit check the internal fuse First disconnect the plug from any mains socket The Transmitter can also be utilized with flying Test leads using one of the optional adaptors The transmitter can work on Tx 100V or 240V circuits 50 or 60Hz f Optional adaptors are ava...
Страница 8: ...ed signal There is a Buzz which sounds at different speed according to the signal strength and indicate other information like low battery see buzzer Infos ON _x There is a ON and an OFF g tprv J Button indicator Please note tihat the sniffer ON has an auto off feature too Button I so if you don t turn it off it will 11 switch off by itself BUZZER There is a Power On I Battery Rx Battery Compartme...
Страница 9: ...o be found is likely to be the one which shows the highest signal strength 6 Features Receiver ON Key The On key is utilized to turn the Sniffer or receiver ON During the turn on procedure the bar graph is illuminated and the buzzer is buzzing a few times so that the user can check all the indicators are working properly This is the Turn on Test procedure OFF The OFF key is utilized to shut down t...
Страница 10: ... Power On indicator Led is a dual Indicator When the tester is turned ON this indicates the tester has been turned on the healthy condition of the battery BATTERY OK INDICATOR As for the Power ON Indicator the same Led indicates that the battery voltage is enough to make tests Should the battery need replacement the led will turn off even if the bar graph still works LED BAR GRAPH The Signal Stren...
Страница 11: ...nd battery life by turning itself Off quicker or devices off 7 Features Transmitter Connections The Transmitter need to be connected to the power source cable which need to be traced or to which the circuit breaker need to be found The connection is done by the plug which is attached on the transmitter There are optional flying leads adaptors for applications which requires other means of connecti...
Страница 12: ... the wire which is connected to the socket in order to verify that the sniffer can detect the transmitter Switch the sniffer OFF The Bar Graph shows that the sniffer can detect the cable which is plugged into the socket That mean that the transmitter is sending the signal and that sniffer can ireceive it The bar graph shows the signal and the buzzer buzz faster too THE SNIFFER CHECKING THAT IT S D...
Страница 13: ...ing the breakers by scanning the breakers using the tip of the sniffer The tip of the sniffer is touching the body of the circuit breaker The bar graph will indicates which circuit breaker has the highest signal strength and the buzzer will buzz faster on the one which has the highest signal strength Turn off that circuit breaker to confirm that it s OFF Turn on again that same circuit breaker to ...
Страница 14: ...the receiver depress the ON button The Bar Graph will lit to show it is in working order 18l t1 The buzzer will beep also to indicate it is in good working order 10 Finding Circuit Breaker c c1v1 lwifil Use the tip of the Sniffer to scan the circuit breakers Please note that the Sniffer is designed to be held vertically for the vertical circuit breakers and horizontally for the horizontal circuit ...
Страница 15: ... While you are scanning observe the bar graph and listen to the buzzer The Circuit breaker which supply the Transmitter circuitry is the one which when pointed out by the tip has the most LEDs lit on the bar graph and the fastest buzz 11 Finding Earth Fault To find an earth fault or the trace faulty wire you must connect the transmitter in serie with the fault 13 ...
Страница 16: ... serie in the line If the Protection device trips then you will have to bypass the protection device for the duration of this test Use the optional leads for this use LINE HOT TRANa lTTElt EARTH GROUND FAULT 12 Notes 14 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...
Страница 17: ...Sniffer is software driven and has an Auto off feature which turn the receiver off automatically after a certain time This timer starts when the Sniffer is turned ON and is not reset by anything Mutli Voltage and Multi Frequency The transmitter has been designed to be able to operate on 100V or 240V circuits at 50 or 60Hz 9V Battery The sniffer uses a 9V batter Due to it s very low consumption any...
Страница 18: ...nals input wires is rectified and an internal power supply is created from that voltage That internal power supply supply all the internal circuitry The transmitter uses an 1OkHz short pulse oscillator to drive a mos fet transistor which in turn will draw current at an approximative 1OkHz frequency This is the current which will be utilized to sniff the wires or circuit breakers 16 ...
Страница 19: ... to a DC level signal The microprocessor reads that smoothed signal which is proportional to the detected signal and display it on a bar graph The Sniffer also has a low battery detector and battery ok circuit which lit the Bat LED when the battery is ok The buzzer is also driven by the microprocessor so that the user can listen to the pulses in conjunction with the bar graph The higher the level ...
Страница 20: ...shown on the Battery OKAnd Tester On indicator Led While the Led lit The battery is OK Vifir ON INDICATOR 17 AUTO OFF The sniffer has an auto off feature and the power automatically turn off after approximatly 3 minutes of being started The Transmitter does not have Auto off and is ON when connected to a power source 18 Preparation for Use Cleaning Use a slightly damped cloth to clean the case Do ...
Страница 21: ...placing the battery This instrument operate well with any type of 9V battery Due to it s very low consumption it does not requires alkaline or any other special type To replace the Battery unfasten the small screw situated at the back of the sniffer Then remove the battery cover Make sure not to loose the screw Remove the bad battery and replace with a new one The battery slide inside the battery ...
Страница 22: ...ries into a purposely dedicated disposal system Do not dispose to the wrong place Look after your environment please 21 Specifications Receiver Tuner Circuit mid frequency 10kHz Battery Voltage 9V 6F22 Bar Graph Leds 9 Battery Indicator Led 1 On button 1 Off Button 1 Buzzer 1 Auto off Min approx 1 20 ...
Страница 23: ...ut current 35mA Frequency of sourced signal 10kHz Size 65 L x50 W x30 D mm Material Polycarbonate ABS Weight Approx 134g with battery Connection Specify type of plug 22 Environmental Operating temperature Range 1 C to 55 C Storage Temperature 20 C to 70 C 23 Cleaning Clean the instrument case with an anti static cleaner and wipe with dry cloth ...
Страница 24: ...ing use of this instrument Our obligation under this warranty is limited to repairing replacing or making refund of this test equipment which proves to be defective within twenty four months from the date of original purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgement to injure their stabili...
Страница 25: ...or any damages or bodily injury which may result from the use or misuse of the product by the purchaser or it s user his employees or others and the remedies provided for in this warranty are expressly in lieu of any other liability we may have including incidental or consequential damages We reserve the right to discontinue models at any time or change specification price or design without notice...
Страница 26: ... 24 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...