k Strip the white (11) and the green (12) wires from cable (1). Leave these two wires unconnected
and cut off the remaining black wire (17) from cable (1).
l
Only the following wires should now be unconnected;
- white wires (11) + (16) and green earth wires (12) + (14) + (18)
- black wire (13) from the Rocker Switch cable
m See Installation Manual (1007718), chapter Electrical Connection, section Connection box, how
to connect the mains power supply cable to the Master Connection box.
n Place the wires in the Master Connection box. Fasten the covers on both Connection boxes and
connect the Interconnection cables to the control unit.
1
10
Master
Slave
Mains power
7
13
14
11
12
6
9
19
Cut the black wire
16
15
18
17
8
Electr
ician N
otice!
Mains Pow
er behind this cover
.
C
onnect to White (Neutral), Black
(HO
T), G
reen (G
N
D
)
D
o not connect to R
ED
.
Slave
Master
Mains power
Cut the black wire
Note! The switch
cannot be
mounted in a 6x6"
header. Place it
inside only.
Note! Connect the sync cable (Kit No. 1008552) in between the two control units and apply
an ”Electrician Notice” label (19) to the cover of the Master mains power connection box.
Electrician Notice!
Mains Power behind this cover.
Connect to White (Neutral), Black
(HOT), Green (GND)
Do not connect to RED.
19
Tip: For convenience tape together 1” from the ends of the following wire combinations in the
Master mains power connection box: Whites (11) + (16), Greens (12) + (14) + (18), Black should
be a single wire.
1009937-EI-1.0
Issue 2013-02-10
52
12 Electrical connection
Содержание SW200i
Страница 26: ...Product label P N 1008999 1009937 EI 1 0 Issue 2013 02 10 26 9 Options...
Страница 30: ...1009937 EI 1 0 Issue 2013 02 10 30 11 Mechanical Installation...
Страница 48: ...11 3 6 Push Pull Arm System double egress 1009937 EI 1 0 Issue 2013 02 10 48 11 Mechanical Installation...
Страница 81: ......