12.3.2
Arm system selection
Factory set arm configuration is PUSH 8 1/4" (210 mm), if other is required:
Select arm configuration on the DIP-switches according to the table below.
ON=1 OFF=0
Spindle location (hinge to outgoing spindle)
Type of arm system
AS 4
DIP 8
AS 3
DIP 7
AS 2
DIP 6
AS 1
DIP 5
0
0
0
0
PUSH, 8 1/4" (210 mm)
Pushing
0
0
0
1
PUSH, 3 3/4" (95 mm)
Pushing
0
0
1
0
PUSH, 2 3/4" (70 mm)
Pushing
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
Concealed (Outswing)
1
0
0
0
PULL, 8 1/4" (210 mm) Reveal 0" - 2 9/16" (0-65 mm)
Pulling PULL
1
0
0
1
PULL, 8 1/4" (210 mm) Reveal 2 9/16" - 5 1/8" (65-130 mm)
Pulling PULL
1
0
1
0
PULL, 3 3/4" (95 mm) Reveal 0" - 2 9/16" (0-65 mm)
PULL, 2 3/4" (70 mm) Reveal 0" - 2 9/16" (0-65 mm)
Pulling PULL/PAS
1
0
1
1
PULL, 3 3/4" (95 mm) Reveal 2 9/16" - 5 1/8" (65-130 mm)
PULL, 2 3/4" (70 mm) Reveal 2 9/16" - 5 1/8" (65-130 mm)
Pulling PULL/PAS
1
1
0
0
1
1
0
1
PULL 210, 8 1/4" (210 mm)
Distance ( Door thi hinge) = 75-130 mm
Sliding push
1
1
1
0
PULL 95, 3 3/4" (95 mm)
Distance ( Door thi hinge) = 0-80 mm
Sliding push/Offset pivot
1
1
1
1
-
Concealed (Inswing)
Note! The Panic Break Out Switch, shall be a normally closed contact, and is only needed at the
Concealed inswing application.
Note! After changing any system selection a new LEARN must be carried out.
1009937-EI-1.0
Issue 2013-02-10
54
12 Electrical connection
Содержание SW200i
Страница 26: ...Product label P N 1008999 1009937 EI 1 0 Issue 2013 02 10 26 9 Options...
Страница 30: ...1009937 EI 1 0 Issue 2013 02 10 30 11 Mechanical Installation...
Страница 48: ...11 3 6 Push Pull Arm System double egress 1009937 EI 1 0 Issue 2013 02 10 48 11 Mechanical Installation...
Страница 81: ......