11.3
Surface Mount Installation
The surface mount operator is used to control all types of swing doors. The operator is mounted
on either side of the door header, and the door is controlled with a push or PAS/pull arm system.
11.3.1
Models
PAS/Pull arm system on a right-handed door shown (header/case side).
Push arm system on a left-handed door shown (header/case side).
Surface Mount Installation
a Establish the installation height and the correct width of the header.
b Open/remove cover.
c Mark and drill the fixing holes and the holes for the cable inlet in the header.
d Mark and drill for cable inlets and mounting holes into the jamb/header (non-pivot side
preferable) for the operator and arm system.
e Install the header using appropriate screws, or if required, Riv-Nuts. Be sure the header is level
left to right as well as front to back.
Note! If installing on a door with swing clear hinges be sure to maintain a maximum distance
of 3 ¾” (95mm) from centerline of spindle to centerline of pivot.
f
Install the external cables through the cable inlet holes. The cables can enter the casing from
the hinge/pivot side or from the strike side, but it is always desirable to bring all wiring in at the
strike side because of the tight conditions between the operator and the end cap.
g Install all electrical components inside header, see page 15.
h Mount the arm system and the door fitting, see page 29.
1009937-EI-1.0
Issue 2013-02-10
34
11 Mechanical Installation
Содержание SW200i
Страница 26: ...Product label P N 1008999 1009937 EI 1 0 Issue 2013 02 10 26 9 Options...
Страница 30: ...1009937 EI 1 0 Issue 2013 02 10 30 11 Mechanical Installation...
Страница 48: ...11 3 6 Push Pull Arm System double egress 1009937 EI 1 0 Issue 2013 02 10 48 11 Mechanical Installation...
Страница 81: ......