4.
MODE
From the display in
Fig.1
, selecting FIELD 3 MODE the display in
Fig. 4
appears.
Fig.4
From the display in
Fig.4
, selecting FIELD 4 PRG T the display in
Fig. 5
appears.
Fig.5
The DISPLAY appears sub-divided in two columns
column 1: Sec. or Min.
column 2: VOLT or AMPERE, based on the initial selection made.
S1, S2, S3, S4, S5, indicating the 5 independent programs you can set.
Fig.5
indicates the 5 programs divided as follows:
S1= 60 seconds at 6.0 volts ;
S2 = 45 seconds at 3.0 volts ;
S3 = 90 seconds at 2.2 volts ;
S4 = 300 seconds at 5.0 volts ;
S5 = 120 seconds at 2.5 volts