01/12/14
Manuale Uso GALVALINK_302B_v3_14 EN Completo
11
6.
USE, MAINTENANCE AND REPAIR; CHECK CORRECT FUNCTIONING
6.1
Intended use of the machine.
The machine was built exclusively for professional use, to plate objects in gold, custom jewellery, watch-
maker and precision mechanics.
ATTENTION:
The machines, by operating, develop vapours due to electrolytic plating,
therefore they should be placed in a working place equipped with an
adequate suction hood.
ATTENTION:
The machine cannot be used in environments where explosive
atmospheres can form.
ATTENTION:
Dispose of used galvanic liquids following the instructions in the reference
SDS Safety Data Sheet of the solutions used.
ATTENTION:
Use only galvanic solutions provided by the manufacturer.
ATTENTION:
During use, the cover of the machine must stay open to enable the
operator to correctly position the material.
ATTENTION:
Connect the machine to an electric system compliant with standards in
force.
ATTENTION:
The operator must wear protective clothing, goggles and gloves and
anything specific in the SDS Safety Data Sheet for the parts used for
galvanic baths.
ATTENTION:
To clean the surfaces dirtied by galvanic liquids, the operator must use
suitable IPD (gloves, apron, goggles, mask to protect the airways).
ATTENTION:
It is forbidden to tamper with the machine.
ATTENTION:
It is forbidden to smoke in the area where the machine is working.
ATTENTION:
Do not insert objects and/or liquids in excess in the Tanks, as they could
cause corrosive and toxic liquid to leak. If this should occur, carefully follow
the instructions outlined in the SDS Safety Data Sheets supplied with the
products used. Carefully and immediately clean the relevant surfaces.
6.2
Correct use of the machine (GALVALINK 302B)
The machine is used by moving the commands and in an emergency situation you can stop the machine
at any time using the main switch
(Fig.3-2)
in position
.
a)
Prepare the electrolytic solutions and fill the tanks on the machine.
The machine contains 2 Pyrex glass tanks as highlighted in
Fig.6.
The Tank on the right (
Fig.6 TANK 2
) is equipped with a thermostatic heater and with an adjustable
stirrer. This Tank is indicated as the galvanic bath (Rhodium, Gold, Silver, Palladium... etc.)
The Tank on the left, instead, (
Fig.6 TANK 1
) is indicated for degreasing operations.
NOTE
The Berkem galvanic systems have anode contacts in both tanks. Therefore, the use sequence of the
galvanic tanks can be modified by the operator, according to the specific needs.
The solutions used (for galvanic baths, degreasing and neutralising baths) must be purchased ready to
use, in order to ensure safe and valid processing. Alternatively, they can be prepared by the operator: in
this case the operator must follow the instructions in the TDS Technical Data Sheets and in the SDS
Содержание GALVALINK 302B
Страница 2: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 2 ...
Страница 23: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 23 ANNEX 3 MEASUREMENTS DRAWING 300mm 340mm 300mm ...
Страница 24: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 24 ANNEX 4 INSTALLATION LAYOUT 1 m 1 m 1 m 1 m ...
Страница 25: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 25 ANNEX 5 ELECTRICAL CIRCUIT DIAGRAM ...
Страница 34: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 34 ...
Страница 35: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 35 ...