![BERGHOF DC1000 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/berghof/dc1000/dc1000_user-manual_2737014060.webp)
USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER
Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com
DC1000_HB_en_2D0982010ZD00.docx | 2VF100108FE04.docx
60
3.3.1. Using the service menu
Touch screen
In Dialog-Controllers with a built-in touch screen, the service menu can be operated directly via screen input.
Keyboard
If the Dialog-Controller is equipped with a keyboard, the following keys are used to operate the service menu:
The cursor block is used to navigate between the indivi-
dual menu items on a given menu level.
The [Enter] key is used to confirm an input.
If a submenu permits values to be modified, this modifica-
tion is performed with the [Enter] key. The [+] / [-] keys
do not function in the service menu. However, using the
cursor block, you can navigate to a “+/-” symbol displayed
on the screen, then use the [Enter] key to either increment
or decrement the associated value.
The [Esc] key is used to exit a menu without saving any
changes which may have been made.
3.3.2. Parameter window
Checking and setting options are accessed through this window section.
The following four menu items are available for selection:
Config
to check and adjust Ethernet parameters, system time and the COM1 serial interface (X4).
PLC
to check and operate the PLC.
Info
to display the hardware and software version levels as well as diagnostic data; and it also offers
the save function (USB, SD, Flash).
Display
to adjust contrast values.
Cursor block
[Enter] key
[Esc] key
Parameter
window structure