2.8. Technical data DC1012 Compact (CP)
Module data
Display
Diagonal measurement
12.1“
Resolution
800 x 600 pixels (VGA)
Colors
65536 (16 bit per pixel)
CPU, application memory
CPU
Freescale PowerPC 400 MHz
Program memory (Flash)
32 MB onboard / 24 MB for application
Program memory and data
memory (RAM)
128 MB onboard / 96 MB for application
Retain memory
16 kB
Development environment
CP1131 (CODESYS 2.3)
Dimensions and weights
Dimensions (WxHxD [mm])
360x260x77 (+6 mm front panel)
Weight
Approx. 6 kg
Operating conditions
Ambient temperature range
0 °C to +55 °C (if installation rule is adhered to)
Relative humidity
Max. 90 %, non-condensing
Transport, storage
Ambient temperature range
-20 °C to +70 °C
Relative humidity
Max. 90 %, non-condensing
Shock resistance
Vibration
Sinusoidal (EN 60068-2-6) test: Fc
10 … 150 Hz, 1 G (operation mode)
Shock resistance
15 G (approx. 150 m/s
2
); duration:10 ms;
semi-sinusoidal (EN 60068-2-27) test: Ea
EMC, protection type
Interference emission
EN 61000-6-4, industrial environments
Interference resistance
EN 61000-6-2, industrial environments
Protection class
III
Insulating resistance
EN 61131-2; DC 500 V test voltage
Protection type
IP20 (front: IP65)