Translated user manual
EasyKit
page 41 of 45
Discharged
Charged battery
The float must be
able to float
freely in order to
read the correct
value
SG scale
t
a
flo
The specific gravity of a fully charged battery should be 1280 g/l:
Before charging, disconnect the
pipe rail wagon
at the
main switch. When charging batteries, always connect
them to the charger before switching it on. After the
batteries have been charged, switch off the charger
first, then disconnect the batteries.
Overcharging can cause damage to the batteries
through boiling the battery acid dry.
It is advisable to use a modern battery charger with an
automatic cut-off - these are available from Berg
Hortimotive.
Use only a charger that is suitable for
the appropriate batteries! (see charger instructions)
The charging process should never be interrupted -
charging should be completed - see the charge
indicator.
When charging batteries, do not make repairs to the
pipe rail wagon
nor carry out cleaning or
any other activities.
Turn off everything that consumes electricity before removing the batteries - this reduces the
possibility of creating sparks.
Always disconnect the earth cable (-) first when removing the batteries. When reinstalling the
batteries, connect the earth cable (black) last.
WARNING!
Always connect the positive terminal (+ = red) to the positive pole and the negative
terminal (- = black) to the negative pole on the battery.
Battery fluid is corrosive - avoid contact with clothing, skin and eyes.
Wash battery acid splashes on clothing or skin immediately with soap and water - thereafter
thoroughly rinse in running water.
If acid splashes into the eyes, rinse them for at least 5 minutes in clean, running water and
call for medical assistance immediately!
Note
Check the number of batteries you can connect up into a single group. This can be calculated by
multiplying the amperage by the voltage. e.g.: 16A*230V =3620W
Now check the output of the battery charger. Divide this total amount by the output of the battery
charger. e.g.: 3620/700=5.17. In this case 5 batteries can be connected.
Also check whether the voltage at the charging location corresponds with the required voltage stated
on the battery charger. Long cables can lead to voltage drop. If this is the case please consult your
dealer.
Check whether it is a suitable charger for your machine. The battery specifications suitable for the
charger are stated on the charger itself!
Only use chargers suitable for charging 24V-110Ah/5h lead/acid batteries! (see charger
instructions) for Pipe rail wagons 150 / 170 / 185 Benomic B-air 1400 / B-air 2000
Only use chargers suitable for charging 24V-60Ah/5h lead/acid batteries! (see charger
instructions) EasyKit
100%
sg 1280 g/l`= 12.7
volts
80%
1240
12.5
60%
1210
12.3
40%
1170
12.1
20%
1140
11.9