68
10
10
10
10
10
.....
D
D
D
D
DA
A
A
A
ATE
TE
TE
TE
TE TEHNICE
TEHNICE
TEHNICE
TEHNICE
TEHNICE
CH:
CH:
CH:
CH:
CH: Putere termica nominala
kW
25,00
34,60
16,0
34,60
kcal/h
21.500
29.756
13.760
29.756
Putere termica nominala (80°/60°)
kW
24,43
33,74
15,6
33,74
kcal/h
21.006
29.012
13,416
29.012
Putere termica nominala (50°/30°)
kW
26,13
36,75
16,8
36,75
kcal/h
22.468
31.601
14,434
31.601
Putere termica redusa
kW
6,00
7,00
3,5
7,00
kcal/h
5.160
6.020
3.010
6.020
Putere termica redusa (80°/60°)
kW
5,86
6,88
3,4
6,88
kcal/h
5.041
5.918
2.890
5.918
Putere termica redusa (50°/30°)
kW
6,44
7,55
3,7
7,55
kcal/h
5.537
6.490
3.148
6.490
(*) DHW:
(*) DHW:
(*) DHW:
(*) DHW:
(*) DHW: Putere termica nominala
kW
25,00
34,60
-
-
kcal/h
21.500
29.756
-
-
Putere termica maxima (**)
kW
25,00
34,60
-
-
kcal/h
21.500
29.756
-
-
Putere termica redusa
kW
6,00
7,00
-
-
kcal/h
5.160
6.020
-
-
Putere termica minima (**)
kW
6,00
7,00
-
-
kcal/h
5.160
6.020
-
-
(**) valori medii masurate la diferite debite de apa
Eficienta de lucru Pn max - Pn min (80-60°)
%
97,7-97,7
97,5-98,3
97,5-96,0
97,5-98,3
Eficienta de lucru 30% (47° retur)
%
101,2
102,1
101,1
102,1
Randamentul combustiei
%
97,9
97,8
97,6
97,8
Eficienta de lucru Pn max - Pn min (50-30°)
%
104,5-107,3 106,2-107,8
104,9-104,6 106,2-107,8
Eficienta de lucru 30% (30° retur)
%
107,1
108,6
107,8
108,6
Putere electrica
W
130
175
130
175
Categorie
II2H3P
II2H3P
II2H3P
II2H3P
Tara
RO
RO
RO
RO
Voltaj alimentare
V - Hz
230-50
230-50
230-50
230-50
Nivel protectie
IP
X5D
X5D
X5D
X5D
Pierderi cos si manta, arzator oprit
%
0,10-0,80
0,10-0,80
0,10-0,80
0,10-0,80
Functionare in regim incalzire
Presiune maxima-temperatura
bar
3-90
3-90
3-90
3-90
Presiune minima pentru operare standard
bar
0,25-0,45
0,25-0,45
0,25-0,45
0,25-0,45
Plaja selectare temperatura apa incalzire
°C
20-80
20-80
20-80
20-80
Pompa: cap coloana maxim pentru capacitatea
mbar
300
300
300
300
sistemului
l/h
1000
1000
1000
1000
Membrana rezervor de expansiune
l
10
10
10
10
Preincarcare vas de expansiune (incalzire
)
bar
1
1
1
1
Functionare in regim ACM*
Presiune maxima
bar
6
6
-
-
Presiune minima
bar
0,15
0,15
-
-
Debit ACM:
∆
t 25° C
l/min
14,3
19,8
-
-
∆
t 30° C
l/min
11,9
16,5
-
-
∆
t 35° C
l/min
10,2
14,2
-
-
Debit minim ACM
l/min
2
2
-
-
Plaja selectare temperatura ACM
°C
35-60
35-60
-
-
Regulator de debit
l/min
10
14
-
-
Presiune gaz
Presiune gaz
Presiune gaz
Presiune gaz
Presiune gaz
Presiune gaz natural (G20)
mbar
20
20
20
20
Presiune LPG (G31)
mbar
37
37
37
37
Conexiuni hidraulice
Incalzire tur-retur
Ø
3/4”
3/4”
3/4”
3/4”
ACM intrare-iesire
(GREEN C.S.I.)
Ø
1/2”
1/2”
-
-
Livrare-retur rezervor apao
(GREEN R.S.I.)
Ø
-
-
3/4”
3/4”
Intrare gaz
Ø
3/4”
3/4”
3/4”
3/4”
Dimensiuni si greutate centrala
Dimensiuni si greutate centrala
Dimensiuni si greutate centrala
Dimensiuni si greutate centrala
Dimensiuni si greutate centrala
Inaltime
mm
845
845
845
845
Lungime
mm
452,5
452,5
452,5
452,5
Latime
mm
358,5
358,5
358,5
358,5
Greutate
kg
44
47
39
43
Performanta ventilator
Performanta ventilator
Performanta ventilator
Performanta ventilator
Performanta ventilator
Pierderi reziduale la ventilator cu tubulatura 0,5 si cot de 90 (aspiratie evacuare)
Pa
110
209
57
209
Rate de debit (G20)
Rate de debit (G20)
Rate de debit (G20)
Rate de debit (G20)
Rate de debit (G20)
Capacitate aer
Nm
3
/h
31,237
43,231
20,446
43,231
Capacitate gaze arse
Nm
3
/h
33,744
46,701
22,050
46,701
Curgere masa fluidizata (max-min)
gr/s
11,31-2,72
15,67-3,17
7,41-1,62
15,67-3,17
Conducte concentrice evacuare gaze si absorbtie aer
Conducte concentrice evacuare gaze si absorbtie aer
Conducte concentrice evacuare gaze si absorbtie aer
Conducte concentrice evacuare gaze si absorbtie aer
Conducte concentrice evacuare gaze si absorbtie aer
Diametru
mm
60-100
60-100
60-100
60-100
Lungime maxima
m
7,80
7,80
7,80
7,80
Pierderi pentru un cot de 90°/45°
m
0,85/0,5
0,85/0,5
0,85/0,5
0,85/0,5
Gaura in perete (diametru)
mm
105
105
105
105
Conducte duble evacuare gaze si absorbtie aer
Conducte duble evacuare gaze si absorbtie aer
Conducte duble evacuare gaze si absorbtie aer
Conducte duble evacuare gaze si absorbtie aer
Conducte duble evacuare gaze si absorbtie aer
Diametru
mm
80
80
80
80
Lungime maxima
m
40+40
50+50
40+40
50+50
Pierderi pentru un cot de 90°/45°
m
0,8/0,5
0,8/0,5
0,8/0,5
0,8/0,5
Noxe
Noxe
Noxe
Noxe
Noxe
clasa 5
clasa 5
clasa 5
clasa 5
V
V
V
V
Va
a
a
a
alor
lor
lor
lor
lori emisii la minim si max
i emisii la minim si max
i emisii la minim si max
i emisii la minim si max
i emisii la minim si maxim g
im g
im g
im g
im gaz G20 ***
az G20 ***
az G20 ***
az G20 ***
az G20 ***
Maxim
Maxim
Maxim
Maxim
Maxim
CO s.a. mai mic decat
p.p.m.
180
250
91
250
CO
2
%
9
9
8,8
9
NOx s.a. mai mic decat
p.p.m.
50
70
16
70
∆
t gaze
°C
34
54
50
54
Minim
Minim
Minim
Minim
Minim
CO s.a. mai mic decat
p.p.m.
40
40
10
40
CO
2
%
9,3
9
9
9
NOx s.a. mai mic decat
p.p.m.
40
60
15
60
∆
t gaze
°C
28
36
39
36
GREEN
C.S.I.
35kW
GREEN
R.S.I.
16kW
*
Valorile ACM valabile pentru modelele GREEN C.S.I.
***
Testate cu tevi
Ø
60-100 concentrice - lung. 0,85m - temp. apa 80-60°C.
GREEN
C.S.I.
25kW
GREEN
R.S.I.
35kW
Содержание EXCLUSIVE GREEN 16 RSI
Страница 91: ...91 EXCLUSIVE GREEN C S I ...
Страница 92: ...92 EXCLUSIVE GREEN R S I ...
Страница 98: ......