ENGLISH
14
CIAO AT 25 C.S.I.
CIAO AT 29 C.S.I.
Seasonal space heating energy efficiency
class
B
Water heating energy efficiency
class
A
Parameter
Symbol
Value Unit
Parameter
Symbol
Value
Unit
Rated heat output
Prated
24
kW
Seasonal space heating energy
efficiency
ηs
86
%
For boiler space heaters and boiler combination heaters:
useful heat output
For boiler space heaters and boiler combination heaters:
useful efficiency
At rated heat output and high-
temperature regime (*)
P4
24,4
kW
At rated heat output and high-
temperature regime (*)
η4
87,7
%
At 30% of rated heat output and
low-temperature regime (**)
P1
7,5
kW
At 30% of rated heat output and
low-temperature regime (**)
η1
90,1
%
Auxiliary electricity consumption
Other parameters
At full load
elmax
90,0
W
Stand-by heat loss
Pstby
40,0
W
At part load
elmin
28,4
W
Pilot flame energy consumption
Pign
-
W
In Stand-by mode
PSB
2,0
W
Annual energy consumption
QHE
82
GJ
Sound power level, indoors
LWA
50
dB
Emissions of nitrogen oxides
NOx
149
mg/
kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
ηwh
81
%
Daily electricity consumption
Qelec
0,220
kWh
Daily fuel consumption
Qfuel
24,122
kWh
Annual electricity consumption
AEC
48
kWh
Annual fuel consumption
AFC
18
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater
inlet).
Seasonal space heating energy efficiency
class
B
Water heating energy efficiency
class
A
Parameter
Symbol
Value
Unit
Parameter
Symbol
Value
Unit
Rated heat output
Prated
28
kW
Seasonal space heating energy
efficiency
ηs
86
%
For boiler space heaters and boiler combination heaters:
useful heat output
For boiler space heaters and boiler combination heaters:
useful efficiency
At rated heat output and high-
temperature regime (*)
P4
28,3
kW
At rated heat output and high-
temperature regime (*)
η4
87,9
%
At 30% of rated heat output and
low-temperature regime (**)
P1
8,7
kW
At 30% of rated heat output and
low-temperature regime (**)
η1
89,6
%
Auxiliary electricity consumption
Other parameters
At full load
elmax
75,0
W
Stand-by heat loss
Pstby
40,0
W
At part load
elmin
23,9
W
Pilot flame energy consumption
Pign
-
W
In Stand-by mode
PSB
2,0
W
Annual energy consumption
QHE
95
GJ
Sound power level, indoors
LWA
50
dB
Emissions of nitrogen oxides
NOx
146
mg/
kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
ηwh
82
%
Daily electricity consumption
Qelec
0,207
kWh
Daily fuel consumption
Qfuel
23,811
kWh
Annual electricity consumption
AEC
45
kWh
Annual fuel consumption
AFC
18
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).