10
ENGLISH
3A SWITCHING OFF
Temporary switching off
In case of absence for short periods of time, set the mode selector
(2 - fig. 1a) to
(OFF).
In this way (leaving the electricity and fuel supplies enabled), the
boiler is protected by the following systems:
-
Anti-frost device:
when the temperature of the water in the
boiler falls below 5°C, the circulator and, if necessary, the
burner are activated at minimum output levels to bring the water
temperature back to the values for safety (35°C). During the anti-
frost cycle, the symbol appears on the digital monitor.
-
Circulator anti-blocking function:
an operation cycle is
activated every 24 hours.
Long period switching off
In case of absence for long periods of time, set the mode selector
(2 - fig. 1a) to
(OFF).
Then, close the gas tap present on the system. In this case, anti-
frost device is deactivated: empty the systems, in case of risk of
frost.
4A CONTROLS
At the beginning of the heating season, and occasionally during
use, make sure the hydrometer-thermohydrometer indicates cold
system pressure values between 0.6 and 1.5 bar: this avoids
system noise levels due to the presence of air. In case of insufficient
water circulation, the boiler will switch off. Under no circumstances,
water pressure must be below 0.5 bar (red field).
If this condition is checked, it is necessary to restore water pressure
in the boiler proceeding as follows:
- set the mode selector (2 - fig.1a) to
(OFF)
- turn on the filling tap (
L
- fig. 12) until the pressure value is
between 1 and 1.5 bar.
Carefully close the tap. Replace the mode selector on the initial
position. If pressure drop is frequent, contact the Technical
Assistance Service.
5A LIGHT SIGNALS AND FAULTS
(fig. 5a)
The operating status of the boiler is shown on the digital display,
below is a list of the types of displays.
BOILER STATUS
DISPLAY
Stand-by
-
OFF status
OFF
ACF module lockout alarm
A01
ACF electrical fault alarm
A01
Limit thermostat alarm
A02
Fumes thermostat
A03
H
2
O pressure switch alarm
A04
NTC domestic water fault
A06
NTC heating fault
A07
Parasite flame
A11
Electric calibration min and max heating
ADJ
Transient awaiting ignition
88°C
flashing
Fumes thermostat intervention
flashing
H
2
O pressure switch intervention
flashing
External probe present
Domestic water heat request
60°C
Heating heat request
80°C
Anti-freeze heat request
Flame present
To restore operation (deactivate alarms):
Faults A 01-02-03
Position the function selector to (OFF), wait 5-6 seconds then
set it to the required position (summer mode) or
(winter
mode). If the reset attempts do not reactivate the boiler, contact the
Technical Assistance Centre.
Fault A04
In addition to the fault code, the digital display shows the symbol .
Check the pressure value indicated by the water gauge:
if it is less than 0.3 bar, position the function selector to (OFF)
and adjust the filling tap
(
L
- fig. 12)
until the pressure reaches a
value between 1 and 1.5 bar.
Then position the mode selector to the desired position
(summer) or
(winter).
If pressure drops are frequent, request the intervention of the
Technical Assistance Service.
Fault A06
The boiler operates normally but cannot reliably maintain a
constant domestic hot water temperature, which remains set at
around 50°C. Contact the Technical Assistance Centre.
Fault A07
Contact the Technical Assistance Centre.