19
English
Fig. 55
D
Working the boiler
Adjust the ambient thermostat to the required temperature (approx.
20 °C). If there is a demand for heating water, the boiler starts
and the symbol is shown on the display (fig. 56). The boiler will
remain working until the set temperatures are reached, after which
it will go on stand-by. In the event of ignition or operating faults,
the boiler will perform a “safety stop”.
The flame symbol
will go out and the fault code and
will
be displayed (fig. 57). For a description of faults and how to reset
them, consult chapter “Troubleshooting”.
Switching off
Switching off for short periods
For brief absences press the
button to switch off the boiler. The
display will show two segments in the central area (fig. 49). When
the boiler remains powered with the gas tap open, it is protected
by the following systems:
- anti-freeze (fig. 58): when the temperature of the water in the
boiler falls below safety values, the circulator and the burner
work at minimum power to increase the water temperature to a
safe value (35 °C). The
symbol lights up on the display.
- circulator anti-block: one operating cycle is performed every
24 hours.
Switching off for long periods
For prolonged absences press the
button to switch off the boiler
(fig. 49). The display will show two segments in the central area.
Turn the main switch to “off”.
Turn off the gas tap under the boiler by turning it clockwise (fig. 59).
In this case, the anti-freeze and anti-block systems are disabled.
Empty the water circuit or suitably protect it with a good make
of anti-freeze.
Fig. 56
Fig. 57
Fig. 58
Fig. 59
tap
closed
Boiler functions
Filling the circuit
If circuit pressure reaches 0.6 bar, the pressure value flashes on
the display (fig. 60a); if it falls below a minimum safety value (0.3
bar), fault code 41 appears on the display (fig. 60b) for a certain
time, following which, if the fault persists, fault code 40 is displayed
(see chapter on “Troubleshooting”).
In the event of faul 40 (fig. 61) proceed as follow to restore the
correct pressure value:
- press button
- open the filling tap external to the boiler, until the pressure shown
in the display is between 1 and 1,5 bar.
If you have to fill the system several times, contact the Technical
Service Centre to check whether the heating circuit is watertight
(see if there are any leaks).
Information
Press , the display turns off and just the word InFO appears (fig.
62). Press the button to view operating information. Press the
button again to move on to the next piece of information. If the
button is not pressed, the system automatically exits the function.
Info list:
Info 0
shows the word InFO (fig. 62)
Info 1
only with the external probe connected, displays external
temperature (e.g. 12 °C) (fig. 63).
The values shown on the display range between - 40 °C
and 40 °C.
Beyond these values the display shows “- -”
Fig. 60a
Fig. 60b
Fig. 61
Fig. 62
Fig. 63
Содержание b11bs
Страница 95: ...95 EXCLUSIVE C A I 86 JP1 AB0X...
Страница 96: ...96 EXCLUSIVE MIX C S I 87 EXCLUSIVE 35 MIX C S I JP1 AB0X...
Страница 97: ...97 EXCLUSIVE R A I 88 JP1 AB0X...
Страница 98: ...98 EXCLUSIVE MIX R S I 89 JP1 AB0X...
Страница 103: ......
Страница 104: ...104 Cod 20029183 09 10 Ed 0 Via Risorgimento 13 23900 Lecco LC ITALY...